Fachartikel in der Zeitschrift Journal of Pathogens, 2012. Verfasst von Qadreyah A Al-Matawah und 4 weiteren Autor:innen. Beteiligte Einrichtung: Biotechnology Department, Kuwait Institute for Scientific Research, Safat 13109, Kuwait. Die Arbeit wurde bisher 15-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Kuwait Institute for Scientific Research.
Abstract (Originalsprache)
The prevalence of Legionella pneumophilia in water systems of residential facilities in Kuwait was performed during the period from November 2007 to November 2011. A total of 204 water samples collected from faucets and showerheads in bathrooms ( n = 82), taps in kitchens ( n = 51), and water tanks ( n = 71), from different locations of residential facilities in Kuwait were screened for Legionella pneumophila by the standard culture method and by real time polymerase chain reaction (RT-PCR). Out of the 204 samples, 89 (43.6%) samples were positive for Legionella spp., 48 (23.5%) samples were detected by the standard culture method, and 85 (41.7%) were detected by RT-PCR. Of the culture positive Legionella samples, counts ranged between 10 to 2250 CFU/L. Serological typing of 48 Legionella isolates revealed that 6 (12.5%) of these isolates belonged to Legionella pneumophila serogroup 1, 37 (77.1%) isolates to Legionella pneumophila serogroup 3, and 1 isolate each (2.1%) belonged to serogroups 4, 7, and 10. The minimum inhibitory concentration (MICs) of the 46 environmental L. pneumophila isolates against the 10 antimicrobials commonly used for Legionella infection treatments were determined. Rifampicin was found to be the most active against L. pneumophila serogroups isolates in vitro .
Autor:innen und Institutionen
- Biotechnology Department, Kuwait Institute for Scientific Research, Safat 13109, Kuwait.
Förderung
- Kuwait Institute for Scientific Research
Zitieren
APA
Al-Matawah, Q. A., Al-Zenki, S. F., Qasem, J. A., Al-Waalan, T. E., & Ben Heji, A. H. (2012). Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities. Journal of Pathogens. https://doi.org/10.1155/2012/138389
Vancouver
Al-Matawah QA, Al-Zenki SF, Qasem JA, Al-Waalan TE, Ben Heji AH. Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities. Journal of Pathogens. 2012. doi:10.1155/2012/138389
BibTeX
@article{AlMatawah2012,
author = {Al-Matawah, Qadreyah A and Al-Zenki, Sameer F and Qasem, Jafer A and Al-Waalan, Tahani E and Ben Heji, Ahmed H},
title = {Detection and Quantification of Legionella pneumophila from Water Systems in Kuwait Residential Facilities},
journal = {Journal of Pathogens},
year = {2012},
doi = {10.1155/2012/138389}
}