EUVIMEDEUVIMED entdecken
FallberichtOpen Access · CC BY 3.0

Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support

Pavel Michalek, Pavel Sebesta, Michael Stern

Case Reports in Vascular Medicine · 2011

DOI: 10.1155/2011/497940 ↗

Kurz gefasst

Fallbericht in der Zeitschrift Case Reports in Vascular Medicine, 2011. Verfasst von Pavel Michalek und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Intensive Care, First Faculty of Medicine, Charles University in Prague and General University Hospital, 128 08 Prag…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

We describe the case of an 83-year-old patient requiring repair of a large symptomatic abdominal aortic aneurysm (AAA). The patient was known to have coronary artery disease (CAD) with symptoms and signs of significant myocardial dysfunction, left-heart failure, and severe aortic insufficiency. The procedure was performed with the help of both mechanical and pharmacological circulatory support. Distal perfusion was provided by an axillofemoral bypass with a centrifugal pump, with dobutamine and levosimendan administered as pharmacological inotropic support. The patient's hemodynamic status was monitored with continuous cardiac output monitoring and transesophageal echocardiography. No serious circulatory complications were recorded during the perioperative and postoperative periods. This paper suggests a potential novel approach to combined circulatory support in patients with heart failure, scheduled for open abdominal aortic aneurysm repair.

Autor:innen und Institutionen

  • Department of Anesthesiology and Intensive Care, First Faculty of Medicine, Charles University in Prague and General University Hospital, 128 08 Prague, Czech Republic.

Zitieren

APA

Michalek, P., Sebesta, P., & Stern, M. (2011). Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support. Case Reports in Vascular Medicine. https://doi.org/10.1155/2011/497940

Vancouver

Michalek P, Sebesta P, Stern M. Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support. Case Reports in Vascular Medicine. 2011. doi:10.1155/2011/497940

BibTeX
@article{Michalek2011,
  author = {Michalek, Pavel and Sebesta, Pavel and Stern, Michael},
  title = {Emergency Abdominal Aortic Aneurysm Repair in a Patient with Failing Heart: Axillofemoral Bypass Using a Centrifugal Pump Combined with Levosimendan for Inotropic Support},
  journal = {Case Reports in Vascular Medicine},
  year = {2011},
  doi = {10.1155/2011/497940}
}
Infokarte | EUVIMED

Artikeldaten derzeit nicht verfügbar.

Recherche