Preoperative Parathyroid Needle Localization: A Minimally Invasive Novel Technique in Reoperative Settings
Minimally Invasive Surgery · 2011
DOI: 10.1155/2011/487076 ↗Kurz gefasst
Fachartikel in der Zeitschrift Minimally Invasive Surgery, 2011. Verfasst von Ryan Winters und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Otolaryngology, Tulane University School of Medicine, New Orleans, LA 70112, USA. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Tulane University.
Abstract (Originalsprache)
Background
Reoperative parathyroid surgery for primary hyperparathyroidism can be challenging. Numerous preoperative localization techniques have been employed to facilitate a more focused surgical exploration. This paper describes a novel, minimally invasive, and highly successful method of parathyroid localization.
Methods
Patients with recurrent or persistent primary hyperparathyroidism underwent parathyroidectomy following CT scan or ultrasound-guided wire localization of the parathyroid. Accurate placement was confirmed by fine-needle aspiration with immunocytochemistry or PTH washout. The guide wire was left in situ to guide surgical excision of the gland. Curative resection was established by monitoring intact serum PTH levels after excision of the adenoma.
Results
All ten patients underwent successful redo-targeted parathyroidectomy. Nine of the ten patients were discharged on the day of surgery. One patient was observed overnight due to transient postoperative hypocalcemia, which resolved with calcium supplementation.
Conclusion
Placement of a localization wire via preoperative high-resolution ultrasound or CT can expedite reoperative parathyroid surgery. It allows identification of parathyroid adenoma via a minimally invasive approach, especially in cases where a sestamibi scan is inconclusive.
Autor:innen und Institutionen
- Department of Otolaryngology, Tulane University School of Medicine, New Orleans, LA 70112, USA.
Förderung
- Tulane University
Zitieren
APA
Winters, R., Friedlander, P., Noureldine, S., Ekaidi, I., Moroz, K., & Kandil, E. (2011). Preoperative Parathyroid Needle Localization: A Minimally Invasive Novel Technique in Reoperative Settings. Minimally Invasive Surgery. https://doi.org/10.1155/2011/487076
Vancouver
Winters R, Friedlander P, Noureldine S, Ekaidi I, Moroz K, Kandil E. Preoperative Parathyroid Needle Localization: A Minimally Invasive Novel Technique in Reoperative Settings. Minimally Invasive Surgery. 2011. doi:10.1155/2011/487076
BibTeX
@article{Winters2011,
author = {Winters, Ryan and Friedlander, Paul and Noureldine, Salem and Ekaidi, Ibrahim and Moroz, Krzysztof and Kandil, Emad},
title = {Preoperative Parathyroid Needle Localization: A Minimally Invasive Novel Technique in Reoperative Settings},
journal = {Minimally Invasive Surgery},
year = {2011},
doi = {10.1155/2011/487076}
}
EUVIMED