EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?

Carlos A Nigro, Eduardo Dibur, Edgardo Rhodius

Sleep Disorders · 2011

DOI: 10.1155/2011/427028 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Sleep Disorders, 2011. Verfasst von Carlos A Nigro und 2 weiteren Autor:innen. Beteiligte Einrichtung: Sleep Laboratory, Hospital Alemán, Pedro Goyena 620, 3 B, CP 1424 Buenos Aires, Argentina. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

To assess the diagnostic ability of WristOx 3100 using its three different recording settings in patients with suspected obstructive sleep apnea syndrome (OSAS).

Methods

All participants (135) performed the oximetry (three oximeters WristOx ) and polysomnography (PSG) simultaneously in the sleep laboratory. Both recordings were interpreted blindly. Each oximeter was set to one of three different recording settings (memory capabilities 0.25, 0.5, and 1 Hz). The software (nVision 5.1) calculated the adjusted O 2 desaturation index-mean number of O 2 desaturation per hour of analyzed recording ≥2, 3, and 4% (ADI2, 3, and 4). The ADI2, 3, and 4 cutoff points that better discriminated between subjects with or without OSAS arose from the receiver-operator characteristics (ROCs) curve analysis. OSAS was defined as a respiratory disturbance index (RDI) ≥ 5.

Results

101 patients were included (77 men, mean age 52, median RDI 22.6, median BMI 27.4 kg/m 2 ). The area under the ROCs curves (AUC-ROCs) of ADI2, 3, and 4 with different data storage rates were similar (AUC-ROCs with data storage rates of 0.25/0.5/1 Hz: ADI2: 0.958/0.948/0.965, ADI3: 0.961/0.95/0.966, and ADI4: 0.957/0.949/0.963, P NS).

Conclusions

The ability of WristOx 3100 to detect patients with OSAS was not affected by the data storage rate of the oxygen saturation signal. Both memory capacity of 0.25, 0.5, or 1 Hz showed a similar performance for the diagnosis of OSAS.

Autor:innen und Institutionen

  • Sleep Laboratory, Hospital Alemán, Pedro Goyena 620, 3 B, CP 1424 Buenos Aires, Argentina.

Zitieren

APA

Nigro, C. A., Dibur, E., & Rhodius, E. (2011). Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?. Sleep Disorders. https://doi.org/10.1155/2011/427028

Vancouver

Nigro CA, Dibur E, Rhodius E. Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?. Sleep Disorders. 2011. doi:10.1155/2011/427028

BibTeX
@article{Nigro2011,
  author = {Nigro, Carlos A and Dibur, Eduardo and Rhodius, Edgardo},
  title = {Pulse Oximetry for the Detection of Obstructive Sleep Apnea Syndrome: Can the Memory Capacity of Oxygen Saturation Influence Their Diagnostic Accuracy?},
  journal = {Sleep Disorders},
  year = {2011},
  doi = {10.1155/2011/427028}
}
Kostenlos starten →