Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery
Pain Research and Treatment · 2011
DOI: 10.1155/2011/362396 ↗Kurz gefasst
Fachartikel in der Zeitschrift Pain Research and Treatment, 2011. Verfasst von André S Nimigan und 1 weiteren Autor:innen. Beteiligte Einrichtung: The Hand and Upper Limb Centre, St. Joseph's Health Centre, The University of Western Ontario, London, ON, Canada N6A 4L6. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 14 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
Purpose
Little attention has been given to syringe design and local anaesthetic administration methods. A microprocessor-controlled anaesthetic delivery device has become available that may minimize discomfort during injection. The purpose of this study was to document the pain experience associated with the use of this system and to compare it with use of a conventional syringe.
Methods
A prospective, randomized clinical trial was designed. 40 patients undergoing carpal tunnel release were block randomized according to sex into a two groups: a traditional syringe group and a microprocessor-controlled device group. The primary outcome measure was surgical pain and local anaesthetic administration pain. Secondary outcomes included volume of anaesthetic used and injection time.
Results
Analysis showed that equivalent anaesthesia was achieved in the microprocessor-controlled group despite using a significantly lower volume of local anaesthetic ( P = .0002 ). This same group, however, has significantly longer injection times ( P < .0001 ). Pain during the injection process or during surgery was not different between the two groups.
Conclusions
This RCT comparing traditional and microprocessor controlled methods of administering local anaesthetic showed similar levels of discomfort in both groups. While the microprocessor-controlled group used less volume, the total time for the administration was significantly greater.
Autor:innen und Institutionen
- The Hand and Upper Limb Centre, St. Joseph's Health Centre, The University of Western Ontario, London, ON, Canada N6A 4L6.
Zitieren
APA
Nimigan, A. S., & Gan, B. S. (2011). Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery. Pain Research and Treatment. https://doi.org/10.1155/2011/362396
Vancouver
Nimigan AS, Gan BS. Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery. Pain Research and Treatment. 2011. doi:10.1155/2011/362396
BibTeX
@article{Nimigan2011,
author = {Nimigan, André S and Gan, Bing Siang},
title = {Pain and Efficacy Rating of a Microprocessor-Controlled Metered Injection System for Local Anaesthesia in Minor Hand Surgery},
journal = {Pain Research and Treatment},
year = {2011},
doi = {10.1155/2011/362396}
}