Fallbericht in der Zeitschrift Case Reports in Ophthalmological Medicine, 2011. Verfasst von Khawla Abu Samra und 2 weiteren Autor:innen. Beteiligte Einrichtung: Ross Eye Institute, The State University of New York at Buffalo, Buffalo, NY 14209, USA. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).
Abstract (Originalsprache)
Purpose
To present a unique case of decompression retinopathy after the implantation of ExPRESS drainage device.
Method
A 25-year-old female patient underwent implantation of ExPRESS drainage device in the left eye for the management of steroid-induced ocular hypertension.
Results
On the postoperative day one, best-corrected visual acuity in the left eye was 20/50. Fundus examination revealed diffuse intraretinal hemorrhages, some white-centered, throughout the retina. There was also marked tortuosity to the retinal vasculature and no evidence of choroidal effusion. Intravenous fluorescein angiography and indocyanine green did not contribute to the aetiopathogenesis.
Conclusion
Decompression retinopathy can occur following the implantation of ExPRESS drainage device. It is very important to be aware of this complication in patients with relatively high intraocular pressure who is planned for filtration surgery, including the ExPRESS implant.
Autor:innen und Institutionen
- Ross Eye Institute, The State University of New York at Buffalo, Buffalo, NY 14209, USA.
Zitieren
APA
Abu Samra, K., Fernando Sieminski, S., & Sarup, V. (2011). Decompression Retinopathy after ExPRESS Shunt Implantation for Steroid-Induced Ocular Hypertension: A Case Report. Case Reports in Ophthalmological Medicine. https://doi.org/10.1155/2011/303287
Vancouver
Abu Samra K, Fernando Sieminski S, Sarup V. Decompression Retinopathy after ExPRESS Shunt Implantation for Steroid-Induced Ocular Hypertension: A Case Report. Case Reports in Ophthalmological Medicine. 2011. doi:10.1155/2011/303287
BibTeX
@article{AbuSamra2011,
author = {Abu Samra, Khawla and Fernando Sieminski, Sandra and Sarup, Vimal},
title = {Decompression Retinopathy after ExPRESS Shunt Implantation for Steroid-Induced Ocular Hypertension: A Case Report},
journal = {Case Reports in Ophthalmological Medicine},
year = {2011},
doi = {10.1155/2011/303287}
}
EUVIMED