The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification
International Journal of Molecular Imaging · 2011
DOI: 10.1155/2011/195037 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Molecular Imaging, 2011. Verfasst von J M Warwick und 5 weiteren Autor:innen. Beteiligte Einrichtung: Nuclear Medicine, Faculty of Health Sciences, Stellenbosch University and Tygerberg Hospital, Tygerberg, 7505, Cape Town, South Africa. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: South African Medical Research Council.
Abstract (Originalsprache)
Purpose
Striatal single photon emission computed tomography (SPECT) imaging of the dopaminergic system is becoming increasingly used for clinical and research studies. The question about the value of nonuniform attenuation correction has become more relevant with the increasing availability of hybrid SPECT-CT scanners. In this study, the value of nonuniform attenuation correction and correction for collimator blurring were determined using both phantom data and patient data.
Methods
SPECT imaging was performed using 7 anthropomorphic phantom measurements, and 14 patient studies using [I-123]-FP-CIT (DATSCAN). SPECT reconstruction was performed using uniform and nonuniform attenuation correction and collimator blurring corrections. Recovery values (phantom data) or average-specific uptake ratios (patient data) for the different reconstructions were compared at similar noise levels.
Results
For the phantom data, improved recovery was found with nonuniform attenuation correction and collimator blurring corrections, with further improvement when performed together. However, for patient data the highest average specific uptake ratio was obtained using collimator blurring correction without nonuniform attenuation correction, probably due to subtle SPECT-CT misregistration.
Conclusions
This study suggests that an optimal brain SPECT reconstruction (in terms of the lowest bias) in patients would include a correction for collimator blurring and uniform attenuation correction.
Autor:innen und Institutionen
- Nuclear Medicine, Faculty of Health Sciences, Stellenbosch University and Tygerberg Hospital, Tygerberg, 7505, Cape Town, South Africa.
Förderung
- South African Medical Research Council
Zitieren
APA
Warwick, J. M., Rubow, S., du Toit, M., Beetge, E., Carey, P., & Dupont, P. (2011). The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification. International Journal of Molecular Imaging. https://doi.org/10.1155/2011/195037
Vancouver
Warwick JM, Rubow S, du Toit M, Beetge E, Carey P, Dupont P. The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification. International Journal of Molecular Imaging. 2011. doi:10.1155/2011/195037
BibTeX
@article{Warwick2011,
author = {Warwick, J M and Rubow, S and du Toit, M and Beetge, E and Carey, P and Dupont, P},
title = {The Role of CT-Based Attenuation Correction and Collimator Blurring Correction in Striatal Spect Quantification},
journal = {International Journal of Molecular Imaging},
year = {2011},
doi = {10.1155/2011/195037}
}
EUVIMED