EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Retrospective Illumination Correction of Retinal Images

Libor Kubecka, Jiri Jan, Radim Kolar

International Journal of Biomedical Imaging · 2010-01 · 2010 (1)

DOI: 10.1155/2010/780262 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Biomedical Imaging, online erschienen am 04.07.2010. Verfasst von Libor Kubecka und 2 weiteren Autor:innen. Beteiligte Einrichtung: The Faculty of Electrical Engineering and Communication, Brno University of Technology, 60200 Brno, Czech Republic. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Ministry of Education, Czech Republic.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

A method for correction of nonhomogenous illumination based on optimization of parameters of B‐spline shading model with respect to Shannon′s entropy is presented. The evaluation of Shannon′s entropy is based on Parzen windowing method (Mangin, 2000) with the spline‐based shading model. This allows us to express the derivatives of the entropy criterion analytically, which enables efficient use of gradient‐based optimization algorithms. Seven different gradient‐ and nongradient‐based optimization algorithms were initially tested on a set of 40 simulated retinal images, generated by a model of the respective image acquisition system. Among the tested optimizers, the gradient‐based optimizer with varying step has shown to have the fastest convergence while providing the best precision. The final algorithm proved to be able of suppressing approximately 70% of the artificially introduced non‐homogenous illumination. To assess the practical utility of the method, it was qualitatively tested on a set of 336 real retinal images; it proved the ability of eliminating the illumination inhomogeneity substantially in most of cases. The application field of this method is especially in preprocessing of retinal images, as preparation for reliable segmentation or registration.

Autor:innen und Institutionen

  • The Faculty of Electrical Engineering and Communication, Brno University of Technology, 60200 Brno, Czech Republic.

Förderung

  • Ministry of Education, Czech Republic

Zitieren

APA

Kubecka, L., Jan, J., & Kolar, R. (2010). Retrospective Illumination Correction of Retinal Images. International Journal of Biomedical Imaging, 2010(1). https://doi.org/10.1155/2010/780262

Vancouver

Kubecka L, Jan J, Kolar R. Retrospective Illumination Correction of Retinal Images. International Journal of Biomedical Imaging. 2010;2010(1). doi:10.1155/2010/780262

BibTeX
@article{Kubecka2010,
  author = {Kubecka, Libor and Jan, Jiri and Kolar, Radim},
  title = {Retrospective Illumination Correction of Retinal Images},
  journal = {International Journal of Biomedical Imaging},
  year = {2010},
  volume = {2010},
  number = {1},
  doi = {10.1155/2010/780262}
}