Potential of Dried Blood Self-Sampling for Cyclosporine C 2 Monitoring in Transplant Outpatients
Journal of Transplantation · 2010
DOI: 10.1155/2010/201918 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Transplantation, 2010. Verfasst von Alexander Benedikt Leichtle und 5 weiteren Autor:innen. Beteiligte Einrichtung: Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University Hospital Leipzig, 04103 Leipzig, Germany. Die Arbeit wurde bisher 24-mal zitiert (Crossref) und nennt 16 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0). Gefördert von: Novartis.
Abstract (Originalsprache)
Background
Close therapeutic drug monitoring of Cyclosporine (CsA) in transplant outpatients is a favourable procedure to maintain the long-term blood drug levels within their respective narrow therapeutic ranges. Compared to basal levels ( C 0 ), CsA peak levels ( C 2 ) are more predictive for transplant rejection. However, the application of C 2 levels is hampered by the precise time of blood sampling and the need of qualified personnel. Therefore, we evaluated a new C 2 self-obtained blood sampling in transplant outpatients using dried capillary and venous blood samples and compared the CsA levels, stability, and clinical practicability of the different procedures.
Methods
55 solid organ transplant recipients were instructed to use single-handed sampling of each 50 μ L capillary blood and dried blood spots by finger prick using standard finger prick devices. We used standardized EDTA-coated capillary blood collection systems and standardized filter paper WS 903. CsA was determined by LC-MS/MS. The patients and technicians also answered a questionnaire on the procedure and sample quality.
Results
The C 0 and C 2 levels from capillary blood collection systems ( C 0 [ng/mL]: 114.5 ± 44.5 ; C 2 : 578.2 ± 222.2 ) and capillary dried blood ( C 0 [ng/mL]: 175.4 ± 137.7 ; C 2 : 743.1 ± 368.1 ) significantly ( P < .01 ) correlated with the drug levels of the venous blood samples ( C 0 [ng/mL]: 97.8 ± 37.4 ; C 2 : 511.2 ± 201.5 ). The correlation at C 0 was ρ cap .-ven . = 0.749, and ρ dried blood-ven = 0.432; at C 2 : ρ cap .-ven . = 0.861 and ρ dried blood-ven = 0.711. The patients preferred the dried blood sampling because of the more simple and less painful procedure. Additionally, the sample quality of self-obtained dried blood spots for LC-MS/MS analytics was superior to the respective capillary blood samples.
Conclusions
C 2 self-obtained dried blood sampling can easily be performed by transplant outpatients and is therefore suitable and cost-effective for close therapeutic drug monitoring.
Autor:innen und Institutionen
- Institute of Laboratory Medicine, Clinical Chemistry and Molecular Diagnostics, University Hospital Leipzig, 04103 Leipzig, Germany.
Förderung
- Novartis
Zitieren
APA
Leichtle, A. B., Ceglarek, U., Witzigmann, H., Gäbel, G., Thiery, J., & Fiedler, G. M. (2010). Potential of Dried Blood Self-Sampling for Cyclosporine C 2 Monitoring in Transplant Outpatients. Journal of Transplantation. https://doi.org/10.1155/2010/201918
Vancouver
Leichtle AB, Ceglarek U, Witzigmann H, Gäbel G, Thiery J, Fiedler GM. Potential of Dried Blood Self-Sampling for Cyclosporine C 2 Monitoring in Transplant Outpatients. Journal of Transplantation. 2010. doi:10.1155/2010/201918
BibTeX
@article{Leichtle2010,
author = {Leichtle, Alexander Benedikt and Ceglarek, Uta and Witzigmann, Helmut and Gäbel, Gábor and Thiery, Joachim and Fiedler, Georg Martin},
title = {Potential of Dried Blood Self-Sampling for Cyclosporine C 2 Monitoring in Transplant Outpatients},
journal = {Journal of Transplantation},
year = {2010},
doi = {10.1155/2010/201918}
}
EUVIMED