EUVIMEDEUVIMED entdecken
Open Access · CC BY 3.0

Direct Percutaneous Endoscopic Jejunostomy: High Completion Rates with Selective Use of a Long Drainage Access Needle

G W Moran, N C Fisher

Diagnostic and Therapeutic Endoscopy · 2009

DOI: 10.1155/2009/520879 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Diagnostic and Therapeutic Endoscopy, 2009. Verfasst von G W Moran und 1 weiteren Autor:innen. Beteiligte Einrichtung: Gastroenterology Department, Russells Hall Hospital, Dudley, West Midlands DY1 2HQ, UK. Die Arbeit wurde bisher 11-mal zitiert (Crossref) und nennt 19 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 3.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Direct percutaneous endoscopic jejunostomy (DPEJ) insertion is a useful technique for artificial nutritional support in selected patients. However, it is technically difficult and most case series report significant procedural failure rates.

Methods

We reviewed our case series of DPEJ insertions, done in a tertiary care referral centre from 2002 to 2008. Patients were selected for DPEJ if they required artificial enteric nutritional support but were unsuitable for endoscopic gastrostomy. Our technique includes selective usage of a long drainage access needle for gut luminal puncture, selective fluoroscopic guidance and selective usage of general anaesthesia.

Results

Of 40 consecutive patients undergoing attempted DPEJ insertion, 39/40 (97.5%) had a successful procedure. Sixteen cases (40%) required the drainage access needle for completion, nineteen cases (47.5%) were done with fluoroscopy, and five cases (12.5%) were done under general anaesthesia. There were no procedural complications.

Conclusions

This technique led to a high completion rate and low complication rate. With appropriate care and expertise, DPEJ insertion is reliable and safe.

Autor:innen und Institutionen

  • Gastroenterology Department, Russells Hall Hospital, Dudley, West Midlands DY1 2HQ, UK.

Zitieren

APA

Moran, G. W., & Fisher, N. C. (2009). Direct Percutaneous Endoscopic Jejunostomy: High Completion Rates with Selective Use of a Long Drainage Access Needle. Diagnostic and Therapeutic Endoscopy. https://doi.org/10.1155/2009/520879

Vancouver

Moran GW, Fisher NC. Direct Percutaneous Endoscopic Jejunostomy: High Completion Rates with Selective Use of a Long Drainage Access Needle. Diagnostic and Therapeutic Endoscopy. 2009. doi:10.1155/2009/520879

BibTeX
@article{Moran2009,
  author = {Moran, G W and Fisher, N C},
  title = {Direct Percutaneous Endoscopic Jejunostomy: High Completion Rates with Selective Use of a Long Drainage Access Needle},
  journal = {Diagnostic and Therapeutic Endoscopy},
  year = {2009},
  doi = {10.1155/2009/520879}
}
Kostenlos starten →