Gas volume corrections in intensive care unit: needed or pointless?
Journal of Applied Physiology · 01.08.2023 · 135 (2) · 334-342
DOI: 10.1152/japplphysiol.00225.2023 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Applied Physiology, erschienen am 01.08.2023. Verfasst von Rosanna D'Albo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany. Hauptthemen laut MEDLINE: Carbon Dioxide, Respiration, Artificial. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Themen: Intensivpflege
Abstract (Originalsprache)
Gas volume conditions are often ignored or unknown in the clinical practice. However, they could have relevance for the calculation of some key variables in ICU setting. This study shows that gas volume corrections are mostly relevant when assessing CO 2 clearance, both in mechanical ventilation and during extracorporeal support, whereas irrelevant for oxygenation assessment of patients. Knowing when the appropriate corrections are needed allows to better understand patients’ clinical conditions and to tailor the treatment.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Anesthesiology, University Medical Center Göttingen, Göttingen, Germany.
- Department of Adult Critical Care, Guy's and St Thomas' NHS Foundation Trust, Health Centre for Human and Applied Physiological Sciences, London, United Kingdom.
ORCID-Profile: Mattia Busana, Luciano Gattinoni
Zitieren
APA
D'Albo, R., Romitti, F., Camporota, L., Moerer, O., Busana, M., & Gattinoni, L. (2023). Gas volume corrections in intensive care unit: needed or pointless?. Journal of Applied Physiology, 135(2), 334-342. https://doi.org/10.1152/japplphysiol.00225.2023
Vancouver
D'Albo R, Romitti F, Camporota L, Moerer O, Busana M, Gattinoni L. Gas volume corrections in intensive care unit: needed or pointless?. Journal of Applied Physiology. 2023;135(2):334-342. doi:10.1152/japplphysiol.00225.2023
BibTeX
@article{DAlbo2023,
author = {D'Albo, Rosanna and Romitti, Federica and Camporota, Luigi and Moerer, Onnen and Busana, Mattia and Gattinoni, Luciano},
title = {Gas volume corrections in intensive care unit: needed or pointless?},
journal = {Journal of Applied Physiology},
year = {2023},
volume = {135},
number = {2},
pages = {334--342},
doi = {10.1152/japplphysiol.00225.2023}
}
EUVIMED