Accelerating Single-Atom Electrocatalyst Development with Laboratory-Based X-Ray Absorption Spectroscopy
ECS Meeting Abstracts · 07.07.2026 · MA2026-01 (47) · 2340-2340
DOI: 10.1149/ma2026-01472340mtgabs ↗Kurz gefasst
Fachartikel in der Zeitschrift ECS Meeting Abstracts, erschienen am 07.07.2026. Verfasst von Fereshteh Rezvani und 3 weiteren Autor:innen.
Abstract (Originalsprache)
Single-atom electrocatalysts (SAECs) have emerged as an important class of materials for clean energy reactions, including the oxygen reduction reaction (ORR), oxygen evolution reaction (OER), hydrogen evolution reaction (HER), and carbon dioxide reduction (CO 2 RR). By isolating catalytically active metal atoms on a suitable support or within a well-defined coordination matrix, SAECs provide excellent atom efficiency, adjustable electronic properties, and high catalytic activity even at very low metal loadings. However, structural and electronic features that control their activity, such as oxidation state, ligand environment, metal–support interactions, and their tendency to agglomerate under electrochemical conditions, are subtle, highly dynamic, and often not visible to traditional bulk or surface techniques. As a result, this field increasingly relies on advanced spectroscopic characterization to accurately examine active sites that drive catalytic behavior. X-ray Absorption Spectroscopy (XAS), which includes X-ray Absorption Near-Edge Structure (XANES) and Extended X-ray Absorption Fine Structure (EXAFS), is a crucial method to study the local electronic and structural environment of electrocatalysts. For single-atom systems in particular, XAS can directly measure oxidation states, identify coordination structures (such as M–N 4 , M–N 2 C 2 , or M–N 3 C 1 sites), determine metal–ligand bond lengths, and distinguish true single atoms from small clusters or growing nanoparticles. XAS further provides the capability to monitor the evolution of active sites under operando conditions, revealing changes in coordination, electron density, and bonding as a function of applied potential, electrolyte composition, cycling history, and temperature. These measurements are critical for understanding how structural changes influence catalytic stability, activity, and deactivation mechanisms. Synchrotron beamlines provide very high X-ray flux, excellent energy resolution, and advanced operando setups, making them ideal for studying very dilute active sites and fast structural changes in electrocatalysts. However, limited beamtime, long proposal and scheduling processes, and complex sample preparation can slow down research progress. In contrast, modern laboratory-based XAS instruments offer continuous, on-demand access to high-quality XANES and EXAFS without these restrictions. This easy access allows routine structural checks, quicker feedback on synthesis and activation steps, and faster optimization of electrocatalyst materials, especially for single-atom catalysts, where confirming metal dispersion, coordination, and stability on a regular basis is critical. Within this context, lab-based XAS provides valuable insight into small but important structural changes related to metal–ligand coordination, support defects, and thermal or electrochemical aging. For example, Fe K-edge XANES can confirm Fe–N x coordination, monitor oxidation-state changes after cycling, or detect early stages of agglomeration in harsh electrolytes. Similarly, Pt or Ni K-edge measurements can compare metal–N 4 and metal–O 4 sites, study support effects, or evaluate synthesis strategies designed to stabilize isolated atoms. Recent improvements in laboratory-based XAS instruments have greatly expanded access to high-quality XAFS measurements. Modern lab spectrometers use synchrotron-quality X-ray optics, efficient detector setups, user-friendly software, and proven, reliable X-ray tubes to provide routine access to K-edge XANES and EXAFS for many 3d transition metals used in electrocatalysis (such as Fe, Co, Ni, Cu, and Mn). These instruments can collect high signal-to-noise spectra from powders, inks, electrodes, membranes, glasses, and catalyst-coated substrates with minimal sample preparation. Most importantly, laboratory XAS offers continuous, on-demand access to structural data, supporting routine QA/QC, benchmarking of new materials, confirmation of metal loading and dispersion, and a platform for testing novel experiments before applying to limited synchrotron beamtime. When combined with electrochemical testing and complementary methods such as XPS, XRD, or TEM, lab-based XAS creates a fast and efficient feedback loop that accelerates material development and reduces risk in large R&D programs.
Zitieren
APA
Rezvani, F., Aronstein, P., Lebens-Higgins, Z., & Mortensen, D. (2026). Accelerating Single-Atom Electrocatalyst Development with Laboratory-Based X-Ray Absorption Spectroscopy. ECS Meeting Abstracts, MA2026-01(47), 2340-2340. https://doi.org/10.1149/ma2026-01472340mtgabs
Vancouver
Rezvani F, Aronstein P, Lebens-Higgins Z, Mortensen D. Accelerating Single-Atom Electrocatalyst Development with Laboratory-Based X-Ray Absorption Spectroscopy. ECS Meeting Abstracts. 2026;MA2026-01(47):2340-2340. doi:10.1149/ma2026-01472340mtgabs
BibTeX
@article{Rezvani2026,
author = {Rezvani, Fereshteh and Aronstein, Paul and Lebens-Higgins, Zachary and Mortensen, Devon},
title = {Accelerating Single-Atom Electrocatalyst Development with Laboratory-Based X-Ray Absorption Spectroscopy},
journal = {ECS Meeting Abstracts},
year = {2026},
volume = {MA2026-01},
number = {47},
pages = {2340--2340},
doi = {10.1149/ma2026-01472340mtgabs}
}
EUVIMED