High Performance Cuprous Oxide@Graphitic Carbon Nitride/Glassy Carbon Electrode Electrochemical Sensor for Simultaneous and Sensitive Detection of Dopamine and Uric Acid
ECS Sensors Plus · 01.09.2026 · 5 (3) · 031602
DOI: 10.1149/2754-2726/ae96be ↗Kurz gefasst
Fachartikel in der Zeitschrift ECS Sensors Plus, online erschienen am 19.08.2026. Verfasst von Saad Benhaiba und 4 weiteren Autor:innen. Die Arbeit nennt 86 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: University of Sharjah.
Abstract (Originalsprache)
This study reports an electrochemical sensor for simultaneous detection of dopamine (DA) and uric acid (UA) using a glassy carbon electrode (GCE) modified with a cuprous-oxide graphitic carbon nitride (Cu 2 O@GCN) nanohybrid. The composite was characterized using XPS, FTIR, SEM‐EDX, and XRD. The latter confirmed the incorporation of cuprous-oxide within the GCN matrix. XPS revealed Cu 2p 1 / 2 and Cu 2p 3 / 2 peaks at 952.6 eV and 932.8 eV, indicating copper in + 1-oxidation state. CV showed an electroactive surface area of 0.1025 cm 2 , while EIS exhibited low charge-transfer resistance ( R ct = 320 Ω), demonstrating efficient electron transport. The sensor displayed a wide linear range of 1–750 µM for simultaneous DA and UA detection, with R 2 = 0.998 and 0.997, and low LOD of 0.40 µM (DA) and 0.25 µM (UA). Excellent reproducibility (RSD = 1.35% and 1.55%) and repeatability (RSD = 1.48% and 1.62%) were achieved. Stability tests showed 97% and 94% retention of initial responses after one week. The sensor also exhibited high selectivity against common interferents. Recoveries in human serum yielded 101%–105%, confirming both accuracy and practical applicability. These findings substantiate the Cuprous-oxide@GCN/GCE sensor as a sensitive, reliable, and selective platform for simultaneous electrochemical determination of DA and UA in biological samples.
Förderung
- University of Sharjah
Zitieren
APA
Benhaiba, S., Elgamouz, A., Kawde, A., Ezzahi, A., & Rhazi, M. E. (2026). High Performance Cuprous Oxide@Graphitic Carbon Nitride/Glassy Carbon Electrode Electrochemical Sensor for Simultaneous and Sensitive Detection of Dopamine and Uric Acid. ECS Sensors Plus, 5(3), 031602. https://doi.org/10.1149/2754-2726/ae96be
Vancouver
Benhaiba S, Elgamouz A, Kawde A, Ezzahi A, Rhazi ME. High Performance Cuprous Oxide@Graphitic Carbon Nitride/Glassy Carbon Electrode Electrochemical Sensor for Simultaneous and Sensitive Detection of Dopamine and Uric Acid. ECS Sensors Plus. 2026;5(3):031602. doi:10.1149/2754-2726/ae96be
BibTeX
@article{Benhaiba2026,
author = {Benhaiba, Saad and Elgamouz, Abdelaziz and Kawde, Abdel-Nasser and Ezzahi, Amine and Rhazi, Mama El},
title = {High Performance Cuprous Oxide@Graphitic Carbon Nitride/Glassy Carbon Electrode Electrochemical Sensor for Simultaneous and Sensitive Detection of Dopamine and Uric Acid},
journal = {ECS Sensors Plus},
year = {2026},
volume = {5},
number = {3},
pages = {031602},
doi = {10.1149/2754-2726/ae96be}
}
EUVIMED