EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sensitive and Sustainable Voltammetric Determination of Gilteritinib Using a SnO 2 /Co 3 O 4 -Modified Carbon Paste Electrode Supported by DFT Analysis

Çiğdem Aybüke Özata, Nevin Erk, Celal Tuğrul Zeyrek, Furkan Uzcan, Mustafa Soylak

ECS Sensors Plus · 01.09.2026 · 5 (3) · 033604

DOI: 10.1149/2754-2726/ae90bd ↗

Kurz gefasst

Fachartikel in der Zeitschrift ECS Sensors Plus, online erschienen am 06.08.2026. Verfasst von Çiğdem Aybüke Özata und 4 weiteren Autor:innen. Die Arbeit nennt 49 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

An electrochemical sensor based on a SnO 2 /Co 3 O 4 -modified carbon paste electrode (CPE) was developed for the quantitative determination of gilteritinib (GIL), a drug used in the treatment of acute myeloid leukemia. The SnO 2 /Co 3 O 4 nanocomposite was synthesized via a precipitation–calcination route and characterized by XRD, FTIR, FE-SEM, and STEM analyses. The electrochemical properties of the modified electrode were investigated using cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS). Compared with bare CPE, the SnO 2 /Co 3 O 4 /CPE exhibited enhanced electrocatalytic activity and faster electron-transfer kinetics, evidenced by lower peak separation (Δ E p = 0.19 V), higher peak current ( I p = 35 µ A), and reduced charge-transfer resistance ( R ct = 2590 Ω). Quantitative determination of GIL was carried out using differential pulse voltammetry (DPV), yielding a wide linear range of 0.00031–11.640 μ M with limits of detection and quantification of 0.093 and 0.309 nM, respectively. The sensor showed excellent repeatability (RSD = 1.1%), reproducibility (RSD = 0.5%), high sensitivity (13.17 µ A µ M −1 cm −2 ), and good selectivity, with recoveries between 96.9% and 103.5%. Greenness assessment using AGREE, GAPI, and BAGI confirmed the environmentally friendly nature of the method. Overall, the proposed platform provides a sensitive and reliable approach for GIL determination with potential application in therapeutic monitoring.

Zitieren

APA

Özata, Ç. A., Erk, N., Zeyrek, C. T., Uzcan, F., & Soylak, M. (2026). Sensitive and Sustainable Voltammetric Determination of Gilteritinib Using a SnO 2 /Co 3 O 4 -Modified Carbon Paste Electrode Supported by DFT Analysis. ECS Sensors Plus, 5(3), 033604. https://doi.org/10.1149/2754-2726/ae90bd

Vancouver

Özata ÇA, Erk N, Zeyrek CT, Uzcan F, Soylak M. Sensitive and Sustainable Voltammetric Determination of Gilteritinib Using a SnO 2 /Co 3 O 4 -Modified Carbon Paste Electrode Supported by DFT Analysis. ECS Sensors Plus. 2026;5(3):033604. doi:10.1149/2754-2726/ae90bd

BibTeX
@article{zata2026,
  author = {Özata, Çiğdem Aybüke and Erk, Nevin and Zeyrek, Celal Tuğrul and Uzcan, Furkan and Soylak, Mustafa},
  title = {Sensitive and Sustainable Voltammetric Determination of Gilteritinib Using a SnO 2 /Co 3 O 4 -Modified Carbon Paste Electrode Supported by DFT Analysis},
  journal = {ECS Sensors Plus},
  year = {2026},
  volume = {5},
  number = {3},
  pages = {033604},
  doi = {10.1149/2754-2726/ae90bd}
}
Kostenlos starten →