A One-Step Electrosynthesized POPD-ERGO Heterointerface Tailored by Response Surface Methodology for Ultra-Trace Ceftriaxone Monitoring
ECS Sensors Plus · 01.06.2026 · 5 (2) · 023602
DOI: 10.1149/2754-2726/ae709a ↗Kurz gefasst
Fachartikel in der Zeitschrift ECS Sensors Plus, online erschienen am 02.06.2026. Verfasst von Nguyen Minh Quang und 2 weiteren Autor:innen. Die Arbeit nennt 33 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
To address the urgent demand for ultra-trace monitoring of the antibiotic ceftriaxone (CTA) in clinical and environmental contexts, a highly sensitive and permselective POPD-ERGO heterointerface was successfully engineered. Rather than relying on traditional multi-step, toxic-chemical reductions, a completely green, simultaneous one-step potentiodynamic strategy was proposed. By this streamlined methodology, the highly conductive network of electrochemically reduced graphene oxide (ERGO) and the anti-fouling matrix of poly( o -phenylenediamine) (POPD) were intimately integrated. Furthermore, to move beyond empirical trial-and-error practices, the fabrication parameters were strictly tailored utilizing a chemometric Response Surface Methodology (RSM). Under the mathematically optimized conditions, a limit of detection (LOD) (0.0031 μM) and a linear dynamic range (0.01–3.00 μM) were recorded. Notably, severe cross-interferences from co-existing biological molecules were effectively completely obstructed by the size-exclusion barrier of the ladder-type polymeric architecture. Finally, the practical reliability of the fabricated sensor was statistically validated in human urine matrices, wherein absolute quantitative agreement with a reference high-performance liquid chromatography (HPLC) method was confirmed ( p = 0.742). Ultimately, this research has successfully provided a robust, easily scalable, and cost-effective analytical tool for routine pharmacovigilance.
Zitieren
APA
Quang, N. M., Tuan, D., & Toan, T. T. T. (2026). A One-Step Electrosynthesized POPD-ERGO Heterointerface Tailored by Response Surface Methodology for Ultra-Trace Ceftriaxone Monitoring. ECS Sensors Plus, 5(2), 023602. https://doi.org/10.1149/2754-2726/ae709a
Vancouver
Quang NM, Tuan D, Toan TTT. A One-Step Electrosynthesized POPD-ERGO Heterointerface Tailored by Response Surface Methodology for Ultra-Trace Ceftriaxone Monitoring. ECS Sensors Plus. 2026;5(2):023602. doi:10.1149/2754-2726/ae709a
BibTeX
@article{Quang2026,
author = {Quang, Nguyen Minh and Tuan, Dinh and Toan, Tran Thanh Tam},
title = {A One-Step Electrosynthesized POPD-ERGO Heterointerface Tailored by Response Surface Methodology for Ultra-Trace Ceftriaxone Monitoring},
journal = {ECS Sensors Plus},
year = {2026},
volume = {5},
number = {2},
pages = {023602},
doi = {10.1149/2754-2726/ae709a}
}