Electrochemical Monitoring of Cadmium Stress in Manihot Esculenta Crantz Using Hydrogen Peroxide as a Functional Biomarker
ECS Sensors Plus · 01.06.2026 · 5 (2) · 020603
DOI: 10.1149/2754-2726/ae670f ↗Kurz gefasst
Fachartikel in der Zeitschrift ECS Sensors Plus, online erschienen am 13.05.2026. Verfasst von Paulo Cesar Bustamante und 6 weiteren Autor:innen. Die Arbeit nennt 48 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Pontificia Universidad Católica del Ecuador.
Abstract (Originalsprache)
An electrochemical method based on differential pulse voltammetry (DPV) employing a glassy carbon electrode was developed for the quantification of H 2 O 2 in Manihot esculenta Crantz cell suspensions derived from tuber explants. Cell cultures were exposed to different concentrations of cadmium (Cd 2+ ) for 24, 48, and 72 h. The analytical protocol exhibited a limit of detection of 10.28 μmol l −1 and a limit of quantification of 51.81 μmol l −1 . Cadmium treatment induced a transient increase in H 2 O 2 levels, consistent with an oxidative burst followed by antioxidant-mediated regulation. This behaviour reflects the dynamic activation of redox signalling pathways in cassava cells under metal stress. Overall, the findings indicate that M. esculenta Crantz may serve as a promising sedentary biomarker for cadmium contamination, providing a sensitive, reproducible, and cost-effective strategy for environmental monitoring in tropical regions.
Förderung
- Pontificia Universidad Católica del Ecuador
Zitieren
APA
Bustamante, P. C., Fernández, L., Espinoza-Montero, P. J., Rodríguez, A., Uribe, R., Ortega-Gallegos, A., & Jadan, M. (2026). Electrochemical Monitoring of Cadmium Stress in Manihot Esculenta Crantz Using Hydrogen Peroxide as a Functional Biomarker. ECS Sensors Plus, 5(2), 020603. https://doi.org/10.1149/2754-2726/ae670f
Vancouver
Bustamante PC, Fernández L, Espinoza-Montero PJ, Rodríguez A, Uribe R, Ortega-Gallegos A, et al. Electrochemical Monitoring of Cadmium Stress in Manihot Esculenta Crantz Using Hydrogen Peroxide as a Functional Biomarker. ECS Sensors Plus. 2026;5(2):020603. doi:10.1149/2754-2726/ae670f
BibTeX
@article{Bustamante2026,
author = {Bustamante, Paulo Cesar and Fernández, Lenys and Espinoza-Montero, Patricio J. and Rodríguez, Augusto and Uribe, Rafael and Ortega-Gallegos, Andrea and Jadan, Mónica},
title = {Electrochemical Monitoring of Cadmium Stress in Manihot Esculenta Crantz Using Hydrogen Peroxide as a Functional Biomarker},
journal = {ECS Sensors Plus},
year = {2026},
volume = {5},
number = {2},
pages = {020603},
doi = {10.1149/2754-2726/ae670f}
}
EUVIMED