EUVIMEDEUVIMED entdecken
Crossref

Physics-Driven Performance Exploration of a Nano-Engineered Dielectric Modulated Cylindrical BioFET

Amit Das, Sudip Biswas, Anjana Bhardwaj, Sonam Rewari, R. S. Gupta

ECS Journal of Solid State Science and Technology · 01.10.2026 · 15 (10) · 103002

DOI: 10.1149/2162-8777/aeaa84 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ECS Journal of Solid State Science and Technology, online erschienen am 09.10.2026. Verfasst von Amit Das und 4 weiteren Autor:innen. Die Arbeit nennt 90 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper comprehensively investigates a compact, nano-engineered and short channel symmetrically doped Cylindrical MOSFET with an I-shaped oxide layer-based biosensor (SCSD-CY-BioFET) for generic label free detection of biomolecules, which offers high sensitivity at ultra-small dimensions. For analyzing the biosensing performance, peak transconductance sensitivity and peak output conductance sensitivity has been presented along with other sensitivity metrics to test reliability and sensitivity of SCSD-CY-BioFET. Present work employs symmetric doping with highly doped source and drain extensions, enhancing carrier injection, drive current, and electrostatic balance while reducing contact resistance—collectively leading to improved sensitivity and signal stability compared to asymmetric doping, which can introduce uneven field distribution and compromise sensing reliability. The sensing capability has been assessed by varying primary parameters like ambient temperature, length, and thickness of cavity. Upshots are shown and characterized using fractional change and percentage change in sensitivity to clearly understand sensitivity pattern. For neutral biomolecules, the percentage sensitivity (relative change) varies from 169.85% (206.382 mV) to 244.22% (296.755 mV) when dielectric constant ( K ) of biomolecule changes from 3 to 10 (considering threshold voltage as metric of biosensing). Similarly, for charged biomolecules, the percentage sensitivity (relative change) varies from 379.91% (461.623 mV) to 16.8% (101.096 mV) when the charge density ( N f ) of biomolecule changes from −10 12 cm −2 to +10 12 cm −2 (considering threshold voltage as metric of biosensing). Compared to the dual sided cavity, source-ended cavity has shown better sensing characteristics than the drain-ended cavity, with an improvement of 0.1 µA (0.1 pa) in on-current (off-current) sensitivity. All the simulations corresponding to this work has been performed using SILVACO ATLAS device simulator. A highly sensitive biosensing action with an ultra-small dimension is justified with the obtained results.

Zitieren

APA

Das, A., Biswas, S., Bhardwaj, A., Rewari, S., & Gupta, R. S. (2026). Physics-Driven Performance Exploration of a Nano-Engineered Dielectric Modulated Cylindrical BioFET. ECS Journal of Solid State Science and Technology, 15(10), 103002. https://doi.org/10.1149/2162-8777/aeaa84

Vancouver

Das A, Biswas S, Bhardwaj A, Rewari S, Gupta RS. Physics-Driven Performance Exploration of a Nano-Engineered Dielectric Modulated Cylindrical BioFET. ECS Journal of Solid State Science and Technology. 2026;15(10):103002. doi:10.1149/2162-8777/aeaa84

BibTeX
@article{Das2026,
  author = {Das, Amit and Biswas, Sudip and Bhardwaj, Anjana and Rewari, Sonam and Gupta, R. S.},
  title = {Physics-Driven Performance Exploration of a Nano-Engineered Dielectric Modulated Cylindrical BioFET},
  journal = {ECS Journal of Solid State Science and Technology},
  year = {2026},
  volume = {15},
  number = {10},
  pages = {103002},
  doi = {10.1149/2162-8777/aeaa84}
}
Kostenlos starten →