EUVIMEDEUVIMED entdecken
Crossref

Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection

Prakash Kumar, Adhidesh S. Kumawat

Journal of The Electrochemical Society · 28.04.2026 · 173 (8) · 087503

DOI: 10.1149/1945-7111/ae5fdf ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of The Electrochemical Society, online erschienen am 24.04.2026. Verfasst von Prakash Kumar und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In this work, a highly efficient non-enzymatic electrochemical glucose sensor was developed using a Nickel/graphene/carbon (Ni/Gr/C) nano-electrocatalyst fabricated on a glassy carbon electrode (GCE). The nano-electrocatalyst was synthesized with a hydrothermal method and subsequently drop-cast onto the electrode surface to enhance electrocatalytic activity and electron-transfer kinetics. Structural and morphological characterizations using X-ray diffraction (XRD), transmission electron microscopy (TEM), field-emission scanning electron microscopy with EDX (FESEM-EDX), Fourier-transform infrared spectroscopy (FTIR), and Raman spectroscopy confirmed high crystallinity, uniform Ni dispersion, and strong Ni-C interactions within the synthesized nano-electrocatalyst. The electrochemical performance was evaluated using cyclic voltammetry (CV), chronoamperometry (CA), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The Ni/Gr/C-modified electrode exhibited an enhanced electrochemically active surface area (54.68 cm 2 ), low charge-transfer resistance, and excellent operational stability. The sensor demonstrated a linear detection range of (0.17–1.67) μM, high sensitivity of 8890 μA.mM −1 .cm −2 , and a low limit of detection of 0.15 μM. Additionally, the developed sensor exhibited strong selectivity toward glucose in the presence of common interferents such as uric acid, ascorbic acid, dopamine, fructose and maltose. Diffusion-controlled kinetics within the potential range of 0.4–0.6 V (vs. Hg/HgO) confirmed reliable quantitative performance, highlighting its potential for point-of-care diabetes diagnostics.

Zitieren

APA

Kumar, P., & Kumawat, A. S. (2026). Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection. Journal of The Electrochemical Society, 173(8), 087503. https://doi.org/10.1149/1945-7111/ae5fdf

Vancouver

Kumar P, Kumawat AS. Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection. Journal of The Electrochemical Society. 2026;173(8):087503. doi:10.1149/1945-7111/ae5fdf

BibTeX
@article{Kumar2026,
  author = {Kumar, Prakash and Kumawat, Adhidesh S.},
  title = {Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection},
  journal = {Journal of The Electrochemical Society},
  year = {2026},
  volume = {173},
  number = {8},
  pages = {087503},
  doi = {10.1149/1945-7111/ae5fdf}
}
Kostenlos starten →