Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection
Journal of The Electrochemical Society · 28.04.2026 · 173 (8) · 087503
DOI: 10.1149/1945-7111/ae5fdf ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of The Electrochemical Society, online erschienen am 24.04.2026. Verfasst von Prakash Kumar und 1 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 57 Literaturangaben.
Abstract (Originalsprache)
In this work, a highly efficient non-enzymatic electrochemical glucose sensor was developed using a Nickel/graphene/carbon (Ni/Gr/C) nano-electrocatalyst fabricated on a glassy carbon electrode (GCE). The nano-electrocatalyst was synthesized with a hydrothermal method and subsequently drop-cast onto the electrode surface to enhance electrocatalytic activity and electron-transfer kinetics. Structural and morphological characterizations using X-ray diffraction (XRD), transmission electron microscopy (TEM), field-emission scanning electron microscopy with EDX (FESEM-EDX), Fourier-transform infrared spectroscopy (FTIR), and Raman spectroscopy confirmed high crystallinity, uniform Ni dispersion, and strong Ni-C interactions within the synthesized nano-electrocatalyst. The electrochemical performance was evaluated using cyclic voltammetry (CV), chronoamperometry (CA), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The Ni/Gr/C-modified electrode exhibited an enhanced electrochemically active surface area (54.68 cm 2 ), low charge-transfer resistance, and excellent operational stability. The sensor demonstrated a linear detection range of (0.17–1.67) μM, high sensitivity of 8890 μA.mM −1 .cm −2 , and a low limit of detection of 0.15 μM. Additionally, the developed sensor exhibited strong selectivity toward glucose in the presence of common interferents such as uric acid, ascorbic acid, dopamine, fructose and maltose. Diffusion-controlled kinetics within the potential range of 0.4–0.6 V (vs. Hg/HgO) confirmed reliable quantitative performance, highlighting its potential for point-of-care diabetes diagnostics.
Zitieren
APA
Kumar, P., & Kumawat, A. S. (2026). Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection. Journal of The Electrochemical Society, 173(8), 087503. https://doi.org/10.1149/1945-7111/ae5fdf
Vancouver
Kumar P, Kumawat AS. Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection. Journal of The Electrochemical Society. 2026;173(8):087503. doi:10.1149/1945-7111/ae5fdf
BibTeX
@article{Kumar2026,
author = {Kumar, Prakash and Kumawat, Adhidesh S.},
title = {Development of Ni/Gr/C Nano-Electrocatalyst for Ultra-Sensitive Non-Enzymatic Electrochemical Glucose Detection},
journal = {Journal of The Electrochemical Society},
year = {2026},
volume = {173},
number = {8},
pages = {087503},
doi = {10.1149/1945-7111/ae5fdf}
}
EUVIMED