EUVIMEDEUVIMED entdecken
Crossref

Electrochemical Impedance Spectroscopy for Rapid Monitoring of Staphylococcus aureus Proliferation and Bacterial Detection

S. Prabhavathi, Swapna M. Gali, Kiran Kumar Tadi, T. Manobala

Journal of The Electrochemical Society · 01.07.2025 · 172 (7) · 077520

DOI: 10.1149/1945-7111/adf25d ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of The Electrochemical Society, online erschienen am 31.07.2025. Verfasst von S. Prabhavathi und 3 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 30 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Biofilms pose challenges such as infection transmission, biofouling, equipment failure, and environmental damage. Despite extensive research, their detection in bioenvironmental systems remains a significant challenge for researchers. Electrochemical impedance spectroscopy (EIS) stands out as an exceptionally sensitive and non-destructive technique for real-time monitoring of biofilms. In this study, we employed EIS to investigate the biofilm formation dynamics of the gram-positive bacterium Staphylococcus aureus ( S.aureus ) on indium-titanium oxide (ITO)-coated polyethylene terephthalate (PET) conductive substrates. Comprehensive characterization of both control and biofilm-coated substrates was carried out using. The temporal evolution of S.aureus biofilm growth was tracked through EIS measurements, revealing a substantial increase in charge transfer resistance as the biofilm matured. The extracellular electron transfer between the biofilm-coated electrode and the electrolyte was assessed by modulating the EIS bias potential at open circuit potential. Linear response in the charge transfer resistance with increased concentration of S.aureus was studied from 1.0 × 10 5 to 1.0 × 10 7 CFU ml −1 with a limit of detection of 3.5 × 10 4 . Overall, this work presents a simple yet highly sensitive biosensor for biofilm detection and growth analysis, eliminating the need for complex substrate modifications.

Zitieren

APA

Prabhavathi, S., Gali, S. M., Tadi, K. K., & Manobala, T. (2025). Electrochemical Impedance Spectroscopy for Rapid Monitoring of Staphylococcus aureus Proliferation and Bacterial Detection. Journal of The Electrochemical Society, 172(7), 077520. https://doi.org/10.1149/1945-7111/adf25d

Vancouver

Prabhavathi S, Gali SM, Tadi KK, Manobala T. Electrochemical Impedance Spectroscopy for Rapid Monitoring of Staphylococcus aureus Proliferation and Bacterial Detection. Journal of The Electrochemical Society. 2025;172(7):077520. doi:10.1149/1945-7111/adf25d

BibTeX
@article{Prabhavathi2025,
  author = {Prabhavathi, S. and Gali, Swapna M. and Tadi, Kiran Kumar and Manobala, T.},
  title = {Electrochemical Impedance Spectroscopy for Rapid Monitoring of Staphylococcus aureus Proliferation and Bacterial Detection},
  journal = {Journal of The Electrochemical Society},
  year = {2025},
  volume = {172},
  number = {7},
  pages = {077520},
  doi = {10.1149/1945-7111/adf25d}
}
Kostenlos starten →