EUVIMEDEUVIMED entdecken
Crossref

Highly Sensitive Electrochemical Detection of Hydroquinone in Wastewater Using Ionic Liquid Grafted rGO-ZrO 2 Nanohybrid-Based Conducting Paper

Mohd. Jamshaiya Raza, Owais Jalil, Riyazuddeen, Devendra Kumar, Chandra Mouli Pandey

Journal of The Electrochemical Society · 01.06.2025 · 172 (6) · 067508

DOI: 10.1149/1945-7111/adde89 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of The Electrochemical Society, online erschienen am 10.06.2025. Verfasst von Mohd. Jamshaiya Raza und 4 weiteren Autor:innen. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 52 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Herein, we envisage the fabrication of conducting paper electrode (CPE) based on ionic liquid (IL)-grafted ZrO 2 nanoparticles and rGO for ultra-sensitive enzymatic detection of hazardous phenolic compounds. The rGO-ZrO 2 nanohybrid has been synthesized using the one-pot hydrothermal technique, followed by the modification with IL to enhance the catalytic activity and conductivity of rGO-ZrO 2 nanohybrid. CPE has been prepared by integrating ILs@rGO-ZrO 2 nanohybrid with the PEDOT: PSS modified Whatsman filter paper. The ILs@rGO-ZrO 2 /CPE has been immersed in different solvents, and its conductivity was assessed using the four-probe method. The conductivity of the ILs@rGO-ZrO 2 /CPE was higher in ethanol (7.58 × 10⁻ 3 S/cm) compared to the electrodes without treatment with any solvent. Further, the laccase enzyme was covalently linked to the ILs@rGO-ZrO 2 /CPE for detecting HQ. The fabricated biosensor depicts a linear response for the detection of HQ in the concentration range of 40 μM to 0.01 μM with a detection limit of 0.01 μM and sensitivity of 0.1408 μA μM −1 cm −2 . The electrochemical results indicate that integrating ILs@rGO-ZrO 2 nanohybrid with the CPE enhances electron transfer and electrocatalytic performance. The validation of the fabricated biosensor with tap and lake water shows an acceptable recovery rate, indicating that the developed method is cost-effective and eco-friendly.

Zitieren

APA

Raza, M. J., Jalil, O., Riyazuddeen, Kumar, D., & Pandey, C. M. (2025). Highly Sensitive Electrochemical Detection of Hydroquinone in Wastewater Using Ionic Liquid Grafted rGO-ZrO 2 Nanohybrid-Based Conducting Paper. Journal of The Electrochemical Society, 172(6), 067508. https://doi.org/10.1149/1945-7111/adde89

Vancouver

Raza MJ, Jalil O, Riyazuddeen, Kumar D, Pandey CM. Highly Sensitive Electrochemical Detection of Hydroquinone in Wastewater Using Ionic Liquid Grafted rGO-ZrO 2 Nanohybrid-Based Conducting Paper. Journal of The Electrochemical Society. 2025;172(6):067508. doi:10.1149/1945-7111/adde89

BibTeX
@article{Raza2025,
  author = {Raza, Mohd. Jamshaiya and Jalil, Owais and Riyazuddeen and Kumar, Devendra and Pandey, Chandra Mouli},
  title = {Highly Sensitive Electrochemical Detection of Hydroquinone in Wastewater Using Ionic Liquid Grafted rGO-ZrO 2 Nanohybrid-Based Conducting Paper},
  journal = {Journal of The Electrochemical Society},
  year = {2025},
  volume = {172},
  number = {6},
  pages = {067508},
  doi = {10.1149/1945-7111/adde89}
}
Kostenlos starten →