Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors
Journal of The Electrochemical Society · 02.09.2024 · 171 (9) · 096511
DOI: 10.1149/1945-7111/ad7c80 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of The Electrochemical Society, online erschienen am 27.09.2024. Verfasst von D. E. Yıldız und 5 weiteren Autor:innen. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 35 Literaturangaben.
Abstract (Originalsprache)
This study presents a comparative analysis of non-enzymatic electrochemical voltammetric sensors, utilizing phenylalanine amino acid metal complexes (M: Ni, Zn, and Co) Polyaniline (PANI) nanocomposites (NCs). The PANI: Zn(Phala) 2 NCs-based sensor detected dopamine (DA) with a sensitivity of 101.18 μAμM −1 cm −2 . The limit of detection (LOD) for the PANI: Zn(Phala) 2 NCs-based sensor was calculated as 0.391 μM. This exceptional sensitivity makes the PANI: Zn(Phala) 2 NCs-based sensor highly promising for potential integration into biomedical test kits. To gain deeper insights into the structural properties of the PANI NCs, scanning electron microscopy (SEM), artificial-intelligence-based SEM, and Fourier transform infrared spectroscopy (FTIR) were employed for characterization. FTIR characterization provided insights into the functional groups of the NCs. The results of this comparative investigation a significant advancement in the field of PANI-based electrochemical sensors designed for DA sensing. The PANI: Zn(Phala) 2 NCs-based sensor show great promise for a range of advanced sensing applications. The Z value of the PANI: Zn(Phala) 2 NCs-based sensor is the lowest among the tested materials, indicating that the conductivity of the PANI: Zn(Phala) 2 layer is higher than that of other active layers. Consequently, the PANI: Zn(Phala) 2 NCs-based sensor achieved higher sensitivity in DA detection.
Zitieren
APA
Yıldız, D. E., Taşaltın, N., Karakuş, S., Gürsu, G., Baytemir, G., & Kose, D. A. (2024). Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors. Journal of The Electrochemical Society, 171(9), 096511. https://doi.org/10.1149/1945-7111/ad7c80
Vancouver
Yıldız DE, Taşaltın N, Karakuş S, Gürsu G, Baytemir G, Kose DA. Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors. Journal of The Electrochemical Society. 2024;171(9):096511. doi:10.1149/1945-7111/ad7c80
BibTeX
@article{Yldz2024,
author = {Yıldız, D. E. and Taşaltın, N. and Karakuş, S. and Gürsu, G. and Baytemir, G. and Kose, D. A.},
title = {Phenylalanine: Amino Acid Metal Non-Enzymatic Electrochemical Voltammetric Sensors},
journal = {Journal of The Electrochemical Society},
year = {2024},
volume = {171},
number = {9},
pages = {096511},
doi = {10.1149/1945-7111/ad7c80}
}