An Investigation of Li-Ion Cell Degradation Caused by Simulated Autoclave Cycles
Journal of The Electrochemical Society · 03.06.2024 · 171 (6) · 060520
DOI: 10.1149/1945-7111/ad5625 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of The Electrochemical Society, online erschienen am 19.06.2024. Verfasst von T. Taskovic und 7 weiteren Autor:innen. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Li[Ni 0.6 Mn 0.4 Co 0.0 ]O 2 /graphite (NMC640, balanced for 4.1 V cut-off) and Li[Ni 0.83 Mn 0.06 Co 0.11 ]O 2 /graphite (Ni83, balanced for 4.06 V cut-off) pouch cells were tested using lab-simulated autoclave conditions. After every cycle, the cells at either 3.4, 3.7, or 3.9 V were placed in a 120°C oven for 40 min to undergo an “autoclave” run, then continued for another cycle. Electrolyte blends using lithium bis(fluorosulfonyl)imide (LiFSI) salt were used to improve the cycle-life of autoclaved cells. The lab autoclave protocol was also performed on LiFePO 4 /graphite (LFP) and NMC commercial cylindrical cells, which were advertised for use in or found in autoclaved medical devices. LFP cells performed poorly in the simulated autoclave tests, while commercial high-temperature-tolerant NMC cylindrical cells and the pouch cells performed similarly. In continuous testing at 85°C, the pouch cells had better capacity retention than both cylindrical cell types. However, the pouch cells suffered from electrolyte permeation through the polymer seals. The pouch cell chemistries incorporated in cylindrical cell format would probably give superior performance to the commercial cells in the autoclave tests. Cell lifetimes were improved when cells were placed into the 120°C oven at a lower voltage suggesting that hospitals should charge Li-ion cells after the autoclaving process instead of standard practice of before.
Zitieren
APA
Taskovic, T., Clarke, A., Harlow, J., Maher, S. M., Tuul, K., Eastwood, E., Johnson, M., & Dahn, J. R. (2024). An Investigation of Li-Ion Cell Degradation Caused by Simulated Autoclave Cycles. Journal of The Electrochemical Society, 171(6), 060520. https://doi.org/10.1149/1945-7111/ad5625
Vancouver
Taskovic T, Clarke A, Harlow J, Maher SM, Tuul K, Eastwood E, et al. An Investigation of Li-Ion Cell Degradation Caused by Simulated Autoclave Cycles. Journal of The Electrochemical Society. 2024;171(6):060520. doi:10.1149/1945-7111/ad5625
BibTeX
@article{Taskovic2024,
author = {Taskovic, T. and Clarke, Alison and Harlow, Jessie and Maher, Sasha Martin and Tuul, Kenneth and Eastwood, Ethan and Johnson, Michel and Dahn, J. R.},
title = {An Investigation of Li-Ion Cell Degradation Caused by Simulated Autoclave Cycles},
journal = {Journal of The Electrochemical Society},
year = {2024},
volume = {171},
number = {6},
pages = {060520},
doi = {10.1149/1945-7111/ad5625}
}