EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

ATR-SEIRAS Method to Measure Interfacial pH during Electrocatalytic Nitrate Reduction on Cu

Elizabeth R. Corson, Jinyu Guo, William A. Tarpeh

Journal of The Electrochemical Society · 01.04.2024 · 171 (4) · 046503

DOI: 10.1149/1945-7111/ad3a22 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of The Electrochemical Society, online erschienen am 15.04.2024. Verfasst von Elizabeth R. Corson und 2 weiteren Autor:innen. Die Arbeit wurde bisher 32-mal zitiert (Crossref) und nennt 42 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Division of Electrical, Communications and Cyber Systems, Basic Energy Sciences, Division of Emerging Frontiers and Multidisciplinary Activities.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study reports the accuracy and applications of an attenuated total reflectance–surface-enhanced infrared absorption spectroscopy (ATR–SEIRAS) technique to indirectly measure the interfacial pH of the electrolyte within 10 nm of the electrocatalyst surface. This technique can be used in situ to study aqueous electrochemical reactions with a calibration range from pH 1–13, time resolution down to 4 s, and an average 95% confidence interval of 14% that varies depending on the pH region (acidic, neutral, or basic). The method is applied here to electrochemical nitrate reduction at a copper cathode to demonstrate its capabilities, but is broadly applicable to any aqueous electrochemical reaction (such as hydrogen evolution, carbon dioxide reduction, or oxygen evolution) and the electrocatalyst may be any SEIRAS-active thin film (e.g., silver, gold, or copper). The time-resolved results show a dramatic increase in the interfacial pH from pH 2–7 in the first minute of operation during both constant current and pulsed current experiments where the bulk pH is unchanged. Attempts to control the pH polarization at the surface by altering the electrochemical operating conditions—lowering the current or increasing the pulse frequency—showed no significant change, demonstrating the challenge of controlling the interfacial pH.

Förderung

  • Division of Electrical, Communications and Cyber Systems
  • Basic Energy Sciences
  • Division of Emerging Frontiers and Multidisciplinary Activities

Zitieren

APA

Corson, E. R., Guo, J., & Tarpeh, W. A. (2024). ATR-SEIRAS Method to Measure Interfacial pH during Electrocatalytic Nitrate Reduction on Cu. Journal of The Electrochemical Society, 171(4), 046503. https://doi.org/10.1149/1945-7111/ad3a22

Vancouver

Corson ER, Guo J, Tarpeh WA. ATR-SEIRAS Method to Measure Interfacial pH during Electrocatalytic Nitrate Reduction on Cu. Journal of The Electrochemical Society. 2024;171(4):046503. doi:10.1149/1945-7111/ad3a22

BibTeX
@article{Corson2024,
  author = {Corson, Elizabeth R. and Guo, Jinyu and Tarpeh, William A.},
  title = {ATR-SEIRAS Method to Measure Interfacial pH during Electrocatalytic Nitrate Reduction on Cu},
  journal = {Journal of The Electrochemical Society},
  year = {2024},
  volume = {171},
  number = {4},
  pages = {046503},
  doi = {10.1149/1945-7111/ad3a22}
}
Kostenlos starten →