Comparison of Human-in-the-Loop Neural Network and Manual Methods for Aortic Diameter Measurement at CT Angiography
Radiology: Cardiothoracic Imaging · 2025
DOI: 10.1148/ryct.240490 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Radiology: Cardiothoracic Imaging, 2025. Verfasst von Prabhvir S Marway und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, University of Michigan, Ann Arbor, Mich. Hauptthemen laut MEDLINE: Computed Tomography Angiography, Neural Networks, Computer, Aorta, Thoracic, Radiographic Image Interpretation, Computer-Assisted. Die Arbeit nennt 20 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS, National Institutes of Health.
Abstract (Originalsprache)
An automated convolutional neural network algorithm with human-in-the-loop validation for tracking thoracic aortic diameters at CT angiography demonstrated stronger agreement with reference standard vascular deformation mapping than manual clinical measurements and may support more efficient longitudinal surveillance.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, University of Michigan, Ann Arbor, Mich.
- Department of Cardiac Surgery, University of Michigan, Ann Arbor, Mich.
- Division of Radiology, University of Wisconsin-Madison, 800 University Bay Dr, Rm 216, Madison, WI 53705.
ORCID-Profile: Prabhvir S Marway, Carlos Alberto Campello Jorge, Nicasius Tjahjadi, Gregory Spahlinger, Nicholas S Burris
Förderung
- NHLBI NIH HHS
- National Institutes of Health
Zitieren
APA
Marway, P. S., Campello Jorge, C. A., Baker, T., Tjahjadi, N., Spahlinger, G., & Burris, N. S. (2025). Comparison of Human-in-the-Loop Neural Network and Manual Methods for Aortic Diameter Measurement at CT Angiography. Radiology: Cardiothoracic Imaging. https://doi.org/10.1148/ryct.240490
Vancouver
Marway PS, Campello Jorge CA, Baker T, Tjahjadi N, Spahlinger G, Burris NS. Comparison of Human-in-the-Loop Neural Network and Manual Methods for Aortic Diameter Measurement at CT Angiography. Radiology: Cardiothoracic Imaging. 2025. doi:10.1148/ryct.240490
BibTeX
@article{Marway2025,
author = {Marway, Prabhvir S and Campello Jorge, Carlos Alberto and Baker, Timothy and Tjahjadi, Nicasius and Spahlinger, Gregory and Burris, Nicholas S},
title = {Comparison of Human-in-the-Loop Neural Network and Manual Methods for Aortic Diameter Measurement at CT Angiography},
journal = {Radiology: Cardiothoracic Imaging},
year = {2025},
doi = {10.1148/ryct.240490}
}
EUVIMED