Diagnostic Performance of Dual-energy CT Normalized Iodine Concentration in the Assessment of Soft-tissue Tumor Recurrence
Radiology: Imaging Cancer · 01.11.2026 · 8 (6)
DOI: 10.1148/rycan.250706 ↗Kurz gefasst
Beobachtungsstudie in der Zeitschrift Radiology: Imaging Cancer, erschienen am 01.11.2026. Verfasst von Yingyi Zhu und 12 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Guangdong Provincial People's Hospital, (Guangdong Academy of Medical Sciences), Southern Medical University, No. 106 Zhongs…. Hauptthemen laut MEDLINE: Neoplasm Recurrence, Local, Tomography, X-Ray Computed, Soft Tissue Neoplasms, Iodine. Die Arbeit nennt 24 Literaturangaben. Gefördert von: Natural Science Foundation of Guangdong Province, PR China.
Abstract (Originalsprache)
Venous phase normalized iodine concentration in dual-energy CT demonstrated good diagnostic performance in the assessment of postoperative recurrence of soft-tissue tumors, with efficacy comparable to that of the apparent diffusion coefficient.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Guangdong Provincial People's Hospital, (Guangdong Academy of Medical Sciences), Southern Medical University, No. 106 Zhongshan Er Rd, Guangzhou 510080, Guangdong, PR China.
- Medical Imaging Department, Foshan Sanshui District People's Hospital, Sanshui Hospital, Zhujiang Hospital of Southern Medical University Foshan, 528100, Guangdong, PR China.
- School of Medicine, South China University of Technology, Guangzhou, Guangdong, PR China.
- Department of Oncology, Guangdong Provincial People's Hospital (Guangdong Academy of Medical Sciences), Southern Medical University, Guangzhou, Guangdong, PR China.
- Department of Radiology, Huizhou First Hospital, Huizhou, Guangdong, PR China.
- Department of Medical Imaging, Fuwai Yunnan Hospital, Chinese Academy of Medical Sciences, Kunming, Yunnan, PR China.
ORCID-Profile: Yuan Yan, Lin Liu, Yunyan Zi, Yu Zhang, Haijun Wu
Förderung
- Natural Science Foundation of Guangdong Province, PR China
Zitieren
APA
Zhu, Y., Yan, Y., Zhuang, J., Liu, L., Zi, Y., Leng, H., Luo, W., Cao, X., Huang, W., Chen, L., Xu, F., Zhang, Y., & Wu, H. (2026). Diagnostic Performance of Dual-energy CT Normalized Iodine Concentration in the Assessment of Soft-tissue Tumor Recurrence. Radiology: Imaging Cancer, 8(6). https://doi.org/10.1148/rycan.250706
Vancouver
Zhu Y, Yan Y, Zhuang J, Liu L, Zi Y, Leng H, et al. Diagnostic Performance of Dual-energy CT Normalized Iodine Concentration in the Assessment of Soft-tissue Tumor Recurrence. Radiology: Imaging Cancer. 2026;8(6). doi:10.1148/rycan.250706
BibTeX
@article{Zhu2026,
author = {Zhu, Yingyi and Yan, Yuan and Zhuang, Jiachun and Liu, Lin and Zi, Yunyan and Leng, Hongjing and Luo, Wei and Cao, Ximing and Huang, Wenhan and Chen, Lina and Xu, Fangpin and Zhang, Yu and Wu, Haijun},
title = {Diagnostic Performance of Dual-energy CT Normalized Iodine Concentration in the Assessment of Soft-tissue Tumor Recurrence},
journal = {Radiology: Imaging Cancer},
year = {2026},
volume = {8},
number = {6},
doi = {10.1148/rycan.250706}
}
EUVIMED