EUVIMEDEUVIMED entdecken
Crossref

Glomerular Filtration Rate Measured Based on Iomeprol Clearance Assessed at CT Urography in Living Kidney Donor Candidates

Thomas Stehlé iD, Félix Wei iD, Séverine Brabant, Alain Luciani iD, Philippe Grimbert, Dominique Prié iD, Edouard Reizine iD, Antoine Durrbach, Sébastien Mulé, Anne Hulin iD, Anna Boueilh, Maxime Blain und 6 weitere

Radiology · 2023

DOI: 10.1148/radiol.230567 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology, 2023. Verfasst von Thomas Stehlé und 17 weiteren Autor:innen. Beteiligte Einrichtung: From the Institut National de la Santé et de la Recherche Médicale (INSERM) U955, Université Paris Est Créteil, Institut Mondor de Recherche Biomédic…. Hauptthemen laut MEDLINE: Kidney Transplantation. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 32 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Estimating glomerular filtration rate (GFR) from serum creatinine can be inaccurate, and current procedures for measuring GFR are time-consuming and cumbersome.

Purpose

To develop a method for measuring GFR based on iomeprol clearance assessed at CT urography in kidney donor candidates and compare this with iohexol clearance (reference standard for measuring GFR). Materials and Methods This cross-sectional retrospective study included data from kidney donor candidates who underwent both iohexol clearance and CT urography between July 2016 and October 2022. CT-measured GFR was calculated as the iomeprol excretion rate in the urinary system between arterial and excretory phases (Hounsfield units times milliliters per minute) divided by a surrogate for serum iomeprol concentration in the aorta at the midpoint (in Hounsfield units). Performance of CT-measured GFR was assessed with use of mean bias (mean difference between CT-measured GFR and iohexol clearance), precision (the distance between quartile 1 and quartile 3 of the bias [quartile 3 minus quartile 1], with a small value indicating high precision), and accuracy (percentage of CT-measured GFR values falling within 10%, 20%, and 30% of iohexol clearance values). Intraobserver agreement was assessed for 30 randomly selected individuals with the Lin concordance correlation coefficient.

Results

A total of 75 kidney donor candidates were included (mean age, 51 years ± 13 [SD]; 45 female). The CT-measured GFR was unbiased (1.1 mL/min/1.73 m2 [95% CI: -1.9, 4.1]) and highly precise (16.2 mL/min/1.73 m2 [quartiles 1 to 3, -6.6 to 9.6]). The accuracy of CT-measured GFR within 10%, 20%, and 30% was 61.3% (95% CI: 50.3, 72.4), 88.0% (95% CI: 80.7, 95.4), and 100%, respectively. Concordance between CT-based GFR measurements taken 2 months apart was almost perfect (correlation coefficient, 0.99 [95% CI: 0.98, 0.99]).

Conclusion

In living kidney donors, GFR measured based on iomeprol clearance assessed at CT urography showed good agreement with GFR measured based on iohexol clearance. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Davenport in this issue.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Kidney TransplantationHumansFemaleMiddle AgedGlomerular Filtration RateIohexolRetrospective StudiesCross-Sectional StudiesUrographyCreatinineTomography, X-Ray ComputedKidneyIopamidol

Substanzen

IohexolCreatinineiomeprolIopamidol

Autor:innen und Institutionen

  • From the Institut National de la Santé et de la Recherche Médicale (INSERM) U955, Université Paris Est Créteil, Institut Mondor de Recherche Biomédicale, Créteil, France (T.S., F.W., A.L., P.G., E.R., S.M., A.H., A.B.,…

ORCID-Profile: Thomas Stehlé, Félix Wei, Alain Luciani, Dominique Prié, Edouard Reizine, Anne Hulin, Cécile-Maud Champy, Paul Brasseur, Florence Canouï-Poitrine, Frédéric Pigneur

Zitieren

APA

Stehlé, T., Wei, F., Brabant, S., Luciani, A., Grimbert, P., Prié, D., Reizine, E., Durrbach, A., Mulé, S., Hulin, A., Boueilh, A., Blain, M., Champy, C. M., Ingels, A., Matignon, M., Brasseur, P., Canouï-Poitrine, F., & Pigneur, F. (2023). Glomerular Filtration Rate Measured Based on Iomeprol Clearance Assessed at CT Urography in Living Kidney Donor Candidates. Radiology. https://doi.org/10.1148/radiol.230567

Vancouver

Stehlé T, Wei F, Brabant S, Luciani A, Grimbert P, Prié D, et al. Glomerular Filtration Rate Measured Based on Iomeprol Clearance Assessed at CT Urography in Living Kidney Donor Candidates. Radiology. 2023. doi:10.1148/radiol.230567

BibTeX
@article{Stehl2023,
  author = {Stehlé, Thomas and Wei, Félix and Brabant, Séverine and Luciani, Alain and Grimbert, Philippe and Prié, Dominique and Reizine, Edouard and Durrbach, Antoine and Mulé, Sébastien and Hulin, Anne and Boueilh, Anna and Blain, Maxime and Champy, Cécile-Maud and Ingels, Alexandre and Matignon, Marie and Brasseur, Paul and Canouï-Poitrine, Florence and Pigneur, Frédéric},
  title = {Glomerular Filtration Rate Measured Based on Iomeprol Clearance Assessed at CT Urography in Living Kidney Donor Candidates},
  journal = {Radiology},
  year = {2023},
  doi = {10.1148/radiol.230567}
}
Kostenlos starten →