EUVIMEDEUVIMED entdecken
Crossref

Photon-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience

Timm Dirrichs iD, Eric Tietz iD, André Rüffer iD, Jens Hanten iD, Thai Duy Nguyen iD, Ebba Dethlefsen iD, Christiane K Kuhl iD

Radiology · 01.06.2023 · 307 (5)

DOI: 10.1148/radiol.223088 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology, erschienen am 01.06.2023. Verfasst von Timm Dirrichs und 6 weiteren Autor:innen. Beteiligte Einrichtung: From the Department of Diagnostic and Interventional Radiology (T.D., E.T., E.D., C.K.K.), Department of Pediatric Heart Surgery (A.R., T.D.N.), and …. Hauptthemen laut MEDLINE: Tomography, X-Ray Computed, Heart Defects, Congenital. Die Arbeit wurde bisher 59-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Photon-counting CT (PCCT) has been shown to improve cardiovascular CT imaging in adults. Data in neonates, infants, and young children under the age of 3 years are missing.

Purpose

To compare image quality and radiation dose of ultrahigh-pitch PCCT with that of ultrahigh-pitch dual-source CT (DSCT) in children suspected of having congenital heart defects. Materials and Methods This is a prospective analysis of existing clinical CT studies in children suspected of having congenital heart defects who underwent contrast-enhanced PCCT or DSCT in the heart and thoracic aorta between January 2019 and October 2022. CT dose index and dose-length product were used to calculate effective radiation dose. Signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were calculated by standardized region-of-interest analysis. SNR and CNR dose ratios were calculated. Visual image quality was assessed by four independent readers on a five-point scale: 5, excellent or absent; 4, good or minimal; 3, moderate; 2, limited or substantial; and 1, poor or massive.

Results

Contrast-enhanced PCCT (n = 30) or DSCT (n = 84) was performed in 113 children (55 female and 58 male participants; median age, 66 days [IQR, 15-270]; median height, 56 cm [IQR, 52-67]; and median weight, 4.5 kg [IQR, 3.4-7.1]). A diagnostic image quality score of at least 3 was obtained in 29 of 30 (97%) with PCCT versus 65 of 84 (77%) with DSCT. Mean overall image quality ratings were higher for PCCT versus DSCT (4.17 vs 3.16, respectively; P < .001). SNR and CNR were higher for PCCT versus DSCT with SNR (46.3 ± 16.3 vs 29.9 ± 15.3, respectively; P = .007) and CNR (62.0 ± 50.3 vs 37.2 ± 20.8, respectively; P = .001). Mean effective radiation doses were similar for PCCT and DSCT (0.50 mSv vs 0.52 mSv; P = .47).

Conclusion

At a similar radiation dose, PCCT offers a higher SNR and CNR and thus better cardiovascular imaging quality than DSCT in children suspected of having cardiac heart defects. © RSNA, 2023.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Tomography, X-Ray ComputedHeart Defects, CongenitalAdultInfant, NewbornChildHumansMaleInfantFemaleChild, PreschoolSignal-To-Noise RatioThoraxLungRadiation Dosage

Autor:innen und Institutionen

  • From the Department of Diagnostic and Interventional Radiology (T.D., E.T., E.D., C.K.K.), Department of Pediatric Heart Surgery (A.R., T.D.N.), and Department of Pediatric Cardiology (J.H.), RWTH Aachen University Hosp…

ORCID-Profile: Timm Dirrichs, Eric Tietz, André Rüffer, Jens Hanten, Thai Duy Nguyen, Ebba Dethlefsen, Christiane K Kuhl

Zitieren

APA

Dirrichs, T., Tietz, E., Rüffer, A., Hanten, J., Nguyen, T. D., Dethlefsen, E., & Kuhl, C. K. (2023). Photon-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience. Radiology, 307(5). https://doi.org/10.1148/radiol.223088

Vancouver

Dirrichs T, Tietz E, Rüffer A, Hanten J, Nguyen TD, Dethlefsen E, et al. Photon-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience. Radiology. 2023;307(5). doi:10.1148/radiol.223088

BibTeX
@article{Dirrichs2023,
  author = {Dirrichs, Timm and Tietz, Eric and Rüffer, André and Hanten, Jens and Nguyen, Thai Duy and Dethlefsen, Ebba and Kuhl, Christiane K},
  title = {Photon-counting versus Dual-Source CT of Congenital Heart Defects in Neonates and Infants: Initial Experience},
  journal = {Radiology},
  year = {2023},
  volume = {307},
  number = {5},
  doi = {10.1148/radiol.223088}
}
Kostenlos starten →