EUVIMEDEUVIMED entdecken
Crossref

Non-intrusive Reprogrammable Device Authentication Using Low-cost Motion Sensors in Wearables

Jerry Cheng, Bofan He, Yan Wang, Zixiao Wang, Tianming Zhao, Hao Wan

ACM Transactions on Internet of Things · 31.05.2026 · 7 (2) · 1-23

DOI: 10.1145/3800951 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACM Transactions on Internet of Things, online erschienen am 22.04.2026. Verfasst von Jerry Cheng und 5 weiteren Autor:innen. Die Arbeit nennt 40 Literaturangaben. Gefördert von: Division of Information and Intelligent Systems, Division of Computing and Communication Foundations, Division of Computer and Network Systems.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The rise of wearables such as fitness trackers and smartwatches has increased the need for strong security to protect personal data. Although two-factor authentication methods improve security, they often require additional user input, making them inconvenient. Recently, hardware flaws in accelerometers and WiFi interfaces have been leveraged to create low-effort two-factor authentication methods. However, these hardware-based device credentials are static, necessitating device replacement if the credentials are compromised. In this study, we introduce an innovative device authentication system that identifies wearables using vibration-based credentials. By utilizing built-in vibration motors and motion sensors (i.e., accelerometers and gyroscopes), our system establishes a unique communication channel to capture the distinct characteristics of each device. Unlike existing methods, our vibration-based credentials are reprogrammable and user-friendly. We develop advanced data processing techniques to minimize the impact of noise, body motion artifacts, and wearing position. We design a lightweight convolutional neural network for feature extraction and device authentication, with a majority vote mechanism to improve identification robustness. Extensive experiments with five different smartwatches demonstrate that our system achieves an average precision of 98% and a recall of 94% under various attacks, demonstrating that including gyroscope data significantly improves performance across different wearing poses and watch orientations.

Förderung

  • Division of Information and Intelligent Systems
  • Division of Computing and Communication Foundations
  • Division of Computer and Network Systems

Zitieren

APA

Cheng, J., He, B., Wang, Y., Wang, Z., Zhao, T., & Wan, H. (2026). Non-intrusive Reprogrammable Device Authentication Using Low-cost Motion Sensors in Wearables. ACM Transactions on Internet of Things, 7(2), 1-23. https://doi.org/10.1145/3800951

Vancouver

Cheng J, He B, Wang Y, Wang Z, Zhao T, Wan H. Non-intrusive Reprogrammable Device Authentication Using Low-cost Motion Sensors in Wearables. ACM Transactions on Internet of Things. 2026;7(2):1-23. doi:10.1145/3800951

BibTeX
@article{Cheng2026,
  author = {Cheng, Jerry and He, Bofan and Wang, Yan and Wang, Zixiao and Zhao, Tianming and Wan, Hao},
  title = {Non-intrusive Reprogrammable Device Authentication Using Low-cost Motion Sensors in Wearables},
  journal = {ACM Transactions on Internet of Things},
  year = {2026},
  volume = {7},
  number = {2},
  pages = {1--23},
  doi = {10.1145/3800951}
}
Kostenlos starten →