EUVIMEDEUVIMED entdecken
Crossref

BreatheBand: A Fine-grained and Robust Respiration Monitor System Using WiFi Signals

Zhengxin Guo, Wenyang Yuan, Linqing Gui, Biyun Sheng, Fu Xiao

ACM Transactions on Sensor Networks · 30.11.2023 · 19 (4) · 1-18

DOI: 10.1145/3582079 ↗

Kurz gefasst

Fachartikel in der Zeitschrift ACM Transactions on Sensor Networks, online erschienen am 16.05.2023. Verfasst von Zhengxin Guo und 4 weiteren Autor:innen. Die Arbeit wurde bisher 33-mal zitiert (Crossref) und nennt 38 Literaturangaben. Gefördert von: National Science Fund for Distinguished Young Scholars of China, The Key Program of the National Natural Science Foundation of China, The Key Research and Development Program of Jiangsu Province.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Respiration is a vital indicator of the state of the human body. Monitoring human respiration enables the realization of a variety of intelligent applications, including smart medical and sleep monitoring. Traditional methods that are dependent upon wearable devices are more costly and inconvenient for users. Recent studies have evidenced that low-cost commodity WiFi devices can be used to accomplish contactless respiration monitoring. In this article, we present BreatheBand, a fine-grained and robust respiration monitoring system based on commercial WiFi signals. We first remove the time-varying phase shift in the channel state information (CSI) by developing the Multi-antenna CSI–Subpopulation Genetic algorithm. Then we separate human respiratory components from WiFi signals by employing subcarrier selection and Independent Component Analysis. Next, applying a Mixed Cluster Gaussian–Hidden Markov Model, we generate a respiration signal resembling that of wearable devices. Finally, we integrate the BreatheBand system into commercial WiFi infrastructure. The results show that the BreatheBand’s respiration signal is remarkably identical to the signal collected by the wearable device in various scenarios. In particular, the mean absolute error of the BreatheBand’s respiration rate is approximately 0.1 bpm, outperforming state-of-the-art algorithms.

Förderung

  • National Science Fund for Distinguished Young Scholars of China
  • The Key Program of the National Natural Science Foundation of China
  • The Key Research and Development Program of Jiangsu Province

Zitieren

APA

Guo, Z., Yuan, W., Gui, L., Sheng, B., & Xiao, F. (2023). BreatheBand: A Fine-grained and Robust Respiration Monitor System Using WiFi Signals. ACM Transactions on Sensor Networks, 19(4), 1-18. https://doi.org/10.1145/3582079

Vancouver

Guo Z, Yuan W, Gui L, Sheng B, Xiao F. BreatheBand: A Fine-grained and Robust Respiration Monitor System Using WiFi Signals. ACM Transactions on Sensor Networks. 2023;19(4):1-18. doi:10.1145/3582079

BibTeX
@article{Guo2023,
  author = {Guo, Zhengxin and Yuan, Wenyang and Gui, Linqing and Sheng, Biyun and Xiao, Fu},
  title = {BreatheBand: A Fine-grained and Robust Respiration Monitor System Using WiFi Signals},
  journal = {ACM Transactions on Sensor Networks},
  year = {2023},
  volume = {19},
  number = {4},
  pages = {1--18},
  doi = {10.1145/3582079}
}
Kostenlos starten →