Addressing Data Center Cooling Needs Through the Use of Reservoir Thermal Energy Storage Systems

Yingqi Zhang, Peng Peng, Hyunjun Oh, Wencheng Jin, Jeff Winick, David Sickinger, Trevor Atkinson, Dale Sartor, Nuoa Lei, Isabelle Sauter, Patrick F. Dobson

Journal of Clean Energy and Energy Storage · 2025-01 · 02

DOI: 10.1142/s2811034x25500029 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Clean Energy and Energy Storage, online erschienen am 02.04.2025. Verfasst von Yingqi Zhang und 10 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 35 Literaturangaben. Gefördert von: Geothermal Technologies Office.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This study investigates using reservoir thermal energy storage (RTES) to reduce the significant energy use and minimize water consumption for data center cooling. Techno-economic analysis was performed for a representative 70 MW hyperscale data center and a 30 MW crypto-mining data center at two representative locations. The investigation shows that both systems are technically feasible and thermally sustainable for at least a period of 20 years without major modifications to the systems. The calculated levelized cost of cooling for using RTES to cool the 70 MW and 30 MW data centers is 11.9 and 14.8 ($/MWh), respectively, and the average cooling provided by RTES is 60% and 36%, respectively. The significance of the RTES cooling is to store cheap cooling in winter and use it in the summer, when cooling is in much more demand. Additional benefits of RTES include enhanced resiliency during high heat events, improved computational efficiency through lower operating temperatures, and significant water conservation by reducing the need for cooling towers. Two key factors contribute to an economically feasible and attractive RTES location: The first is a shallow, non-potable water-bearing geological formation with high transmissivity to maximize storage capacity and minimize the drilling cost. The second key factor is the potential to use free or inexpensive cooling for both direct data center cooling and RTES cooling. Future studies should consider using chillers for RTES cooling when there is a significant electric grid value to do so (large difference between peak and off-peak power cost), as well as system optimization.

Förderung

  • Geothermal Technologies Office

Zitieren

APA

Zhang, Y., Peng, P., Oh, H., Jin, W., Winick, J., Sickinger, D., Atkinson, T., Sartor, D., Lei, N., Sauter, I., & Dobson, P. F. (2025). Addressing Data Center Cooling Needs Through the Use of Reservoir Thermal Energy Storage Systems. Journal of Clean Energy and Energy Storage, 02. https://doi.org/10.1142/s2811034x25500029

Vancouver

Zhang Y, Peng P, Oh H, Jin W, Winick J, Sickinger D, et al. Addressing Data Center Cooling Needs Through the Use of Reservoir Thermal Energy Storage Systems. Journal of Clean Energy and Energy Storage. 2025;02. doi:10.1142/s2811034x25500029

BibTeX
@article{Zhang2025,
  author = {Zhang, Yingqi and Peng, Peng and Oh, Hyunjun and Jin, Wencheng and Winick, Jeff and Sickinger, David and Atkinson, Trevor and Sartor, Dale and Lei, Nuoa and Sauter, Isabelle and Dobson, Patrick F.},
  title = {Addressing Data Center Cooling Needs Through the Use of Reservoir Thermal Energy Storage Systems},
  journal = {Journal of Clean Energy and Energy Storage},
  year = {2025},
  volume = {02},
  doi = {10.1142/s2811034x25500029}
}
Kostenlos starten →