Review on Cooling System Energy Consumption in Internet Data Centers

Kofi Owura Amoabeng, Jong Min Choi

International Journal of Air-Conditioning and Refrigeration · 2016-12 · 24 (04) · 1630008

DOI: 10.1142/s2010132516300081 ↗

Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Air-Conditioning and Refrigeration, online erschienen am 27.12.2016. Verfasst von Kofi Owura Amoabeng und 1 weiteren Autor:innen. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 39 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Due to the advancement of the telecommunication and information technology (IT) industry, internet data centers (IDCs) have become widespread in the public and private sectors. As such, energy demand in the center has also become increasingly prominent. Several technologies on energy management have been studied to determine the options available to minimize the energy required to operate the data center as well as reduce greenhouse gas emissions. The cooling system is required to remove the high heat dissipated by the IT electronic components especially the servers in order to ensure safe and reliable working condition. However, it utilizes more than one-third of the total energy consumption in the data center. In this study, the energy efficiency technologies that are usually applied to cooling systems in data centers were reviewed. The aim is to find out the strategies that will reduce the energy consumption of the cooling system since the cooling demand in data center is all year round. Prior to that, the performance metric tool that is mostly used in analyzing data center efficiency was discussed. The conventional cooling system technologies that are utilized in data centers were also provided. Lastly, innovative cooling technologies for future solutions in data centers were discussed.

Zitieren

APA

Amoabeng, K. O., & Choi, J. M. (2016). Review on Cooling System Energy Consumption in Internet Data Centers. International Journal of Air-Conditioning and Refrigeration, 24(04), 1630008. https://doi.org/10.1142/s2010132516300081

Vancouver

Amoabeng KO, Choi JM. Review on Cooling System Energy Consumption in Internet Data Centers. International Journal of Air-Conditioning and Refrigeration. 2016;24(04):1630008. doi:10.1142/s2010132516300081

BibTeX
@article{Amoabeng2016,
  author = {Amoabeng, Kofi Owura and Choi, Jong Min},
  title = {Review on Cooling System Energy Consumption in Internet Data Centers},
  journal = {International Journal of Air-Conditioning and Refrigeration},
  year = {2016},
  volume = {24},
  number = {04},
  pages = {1630008},
  doi = {10.1142/s2010132516300081}
}
Kostenlos starten →