Abstract (Originalsprache)
There are many attempts to use a fuel cell system as a residential power generation system. The purpose of this study is to investigate the optimal design of a water tank for a hot water system when the fuel cell co-generation system is combined with a domestic hot water supply system. The demands of hot water supply per month per home for 76–168 m 2 of acreage are investigated in Busan for a year. It showed somewhat large differences between the actual demand and the designed demand of hot water, but the actual capacity of hourly averaged hot water demands is analyzed as 60 ℓ/h in this study based on the actual demand. The experiments are performed in the various inlet and outlet locations of nozzles in the hot water tank, and the hot water consumption rates. The experimental results showed that the optimal capacity of the water tank is 200 ℓ when the thermal efficiency, the storing capacity of hot water and the space for installation are considered.
Zitieren
APA
HWANG, Y., AHN, Y., CHEONG, S., JIN, K., & LEE, J. (2010). EXPERIMENTAL INVESTIGATION ON THE OPTIMAL DESIGN OF WATER TANK FOR DOMESTIC HOT WATER SUPPLY USING PEMFC CO-GENERATION SYSTEM. International Journal of Air-Conditioning and Refrigeration. https://doi.org/10.1142/s2010132510000113
Vancouver
HWANG Y, AHN Y, CHEONG S, JIN K, LEE J. EXPERIMENTAL INVESTIGATION ON THE OPTIMAL DESIGN OF WATER TANK FOR DOMESTIC HOT WATER SUPPLY USING PEMFC CO-GENERATION SYSTEM. International Journal of Air-Conditioning and Refrigeration. 2010. doi:10.1142/s2010132510000113
BibTeX
@article{HWANG2010,
author = {HWANG, YUJIN and AHN, YOUNGCHULL and CHEONG, SEONGIR and JIN, KEUNHO and LEE, JAEKUEN},
title = {EXPERIMENTAL INVESTIGATION ON THE OPTIMAL DESIGN OF WATER TANK FOR DOMESTIC HOT WATER SUPPLY USING PEMFC CO-GENERATION SYSTEM},
journal = {International Journal of Air-Conditioning and Refrigeration},
year = {2010},
doi = {10.1142/s2010132510000113}
}
EUVIMED