EUVIMEDEUVIMED entdecken
Open Access

The effect of the type of foam pad used in the modified Clinical Test of Sensory Interaction and Balance (mCTSIB) on the accuracy in identifying older adults with fall history

Rumpa Boonsinsukh iD, Bodin Khumnonchai, Vitoon Saengsirisuwan iD, Nithinun Chaikeeree iD

Hong Kong Physiotherapy Journal · 2020-12 · 40 (02) · 133-143

DOI: 10.1142/s1013702520500134 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Hong Kong Physiotherapy Journal, online erschienen am 25.07.2020. Verfasst von Rumpa Boonsinsukh und 3 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Physical Therapy, Srinakharinwirot University, Nakhon Nayok, Thailand. Die Arbeit wurde bisher 17-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: Graduate School, Srinakharinwirot University.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The type of foam pad used in the modified Clinical Test of Sensory Interaction and Balance (mCTSIB) influences the accuracy with which elderly fallers are identified. Two types of foam are commonly used in practice: Airex and Neurocom foam.

Objective

The aim of this study was to assess the accuracy with which elderly fallers can be identified when the Airex foam and Neurocom foam are used in the mCTSIB.

Methods

One hundred eighty-four elderly participants with a mean age of 69 years were classified into faller and nonfaller groups based on their 12-month fall history. Balance stability was measured under four conditions of the mCTSIB for 120 s each: standing on a floor or a foam pad with their eyes open or eyes closed. The time needed to maintain stability was measured by a stopwatch, and postural sway characteristics were measured using an acceleration-based system. Comparisons between groups were performed by two-way mixed ANOVA. The accuracy of differentiating elderly fallers from nonfallers with different foam types was evaluated using receiver operating characteristic curve (ROC) analysis. The time to maintain stability under four conditions of the mCTSIB (composite score) and under two conditions on the foam (foam score) were used for the ROC analysis.

Results

The results showed that the nonfallers required more time to maintain stability and had a smaller sway area than the fallers ([Formula: see text]). The foam led to a larger difference between groups, suggesting the use of foam in examining the risk of falls. The Airex and the Neurocom foam pads led to a large area under the curve (0.93 to 0.95) in identifying elderly fallers and nonfallers when the composite and foam scores were used. A cutoff score of 447/480 s for the composite score and 223/240 s for the foam score yielded a posttest accuracy of 88% to 89%, with a sensitivity of 0.80–0.92 and specificity of 0.88–0.95.

Conclusion

In conclusion, Airex and Neurocom foam can be used interchangeably with guidance in the mCTSIB, as they led to the accurate identification of elderly fallers among older persons who could walk and live independently in the community.

Schlagwörter

Stichwörter der Autor:innen

Fallsolder adultpostural stabilitysensory integration

Autor:innen und Institutionen

  • Faculty of Physical Therapy, Srinakharinwirot University, Nakhon Nayok, Thailand.
  • Faculty of Physical Therapy and Sport Medicine, Rangsit University, Pathum Thani, Thailand.
  • Department of Physiology, Faculty of Science, Mahidol University, Bangkok, Thailand.

ORCID-Profile: Rumpa Boonsinsukh, Vitoon Saengsirisuwan, Nithinun Chaikeeree

Förderung

  • Graduate School, Srinakharinwirot University

Zitieren

APA

Boonsinsukh, R., Khumnonchai, B., Saengsirisuwan, V., & Chaikeeree, N. (2020). The effect of the type of foam pad used in the modified Clinical Test of Sensory Interaction and Balance (mCTSIB) on the accuracy in identifying older adults with fall history. Hong Kong Physiotherapy Journal, 40(02), 133-143. https://doi.org/10.1142/s1013702520500134

Vancouver

Boonsinsukh R, Khumnonchai B, Saengsirisuwan V, Chaikeeree N. The effect of the type of foam pad used in the modified Clinical Test of Sensory Interaction and Balance (mCTSIB) on the accuracy in identifying older adults with fall history. Hong Kong Physiotherapy Journal. 2020;40(02):133-143. doi:10.1142/s1013702520500134

BibTeX
@article{Boonsinsukh2020,
  author = {Boonsinsukh, Rumpa and Khumnonchai, Bodin and Saengsirisuwan, Vitoon and Chaikeeree, Nithinun},
  title = {The effect of the type of foam pad used in the modified Clinical Test of Sensory Interaction and Balance (mCTSIB) on the accuracy in identifying older adults with fall history},
  journal = {Hong Kong Physiotherapy Journal},
  year = {2020},
  volume = {40},
  number = {02},
  pages = {133--143},
  doi = {10.1142/s1013702520500134}
}
Kostenlos starten →