Kurz gefasst

Fachartikel in der Zeitschrift International Journal of Computational Methods, online erschienen am 15.04.2026. Verfasst von Jianguo Xu und 6 weiteren Autor:innen. Die Arbeit nennt 39 Literaturangaben. Gefördert von: National Natural Science Foundation of China project.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

By addressing the computational inefficiency and limited adaptability of existing methods for aqueduct seismic analysis, this study proposes a novel Curvature-Continuous Spline Finite Strip Method (CC-SFSM) for high-precision Fluid–Structure Interaction (FSI) modeling of large-scale aqueducts. The CC-SFSM integrates bending and plane-stress spline rectangular strip elements to discretize the aqueduct body and incorporates Housner’s equivalent spring-mass model for fluid sloshing effects. Validated through shaking table tests and benchmarked against theoretical solutions and conventional finite element software, the method demonstrates ultra-high accuracy (critical displacement/moment errors [Formula: see text]5%) and exceptional computational efficiency (40–66% faster than spatial beam element modeling). Application to the Laozhang Aqueduct (Middle Route, South-to-North Water Diversion Project) reveals that: (1) natural frequencies decrease stepwise with rising water levels, while frequency order dominates modal characteristics; (2) critical displacements (mid-span, pier tops) and expansion joint relative fold angles increase nonlinearly with water level, peaking under full-trough conditions due to fluid inertia; (3) expansion joint angles at pier 3 exceed those at pier 2 by 88.58%, with timing fluctuations attributed to post-impact fluid vibrations. The CC-SFSM uniquely enables direct calculation of joint fold angles, bypassing error-prone transformations in existing approaches. This work advances seismic reliability assessment for hydraulic thin-walled structures and establishes CC-SFSM as an efficient, high-fidelity tool for complex FSI analysis.

Förderung

  • National Natural Science Foundation of China project

Zitieren

APA

Xu, J., Guo, Y., Wang, J., Xiao, Z., Huang, L., Liang, C., & Kou, L. (2026). Seismic Response Analysis of Dual-Chamber Aqueduct Structure with Fluid–Structure Interaction Based on CC-SFSM. International Journal of Computational Methods, 23(08). https://doi.org/10.1142/s0219876226500210

Vancouver

Xu J, Guo Y, Wang J, Xiao Z, Huang L, Liang C, et al. Seismic Response Analysis of Dual-Chamber Aqueduct Structure with Fluid–Structure Interaction Based on CC-SFSM. International Journal of Computational Methods. 2026;23(08). doi:10.1142/s0219876226500210

BibTeX
@article{Xu2026,
  author = {Xu, Jianguo and Guo, Yihang and Wang, Jiangfei and Xiao, Zhongyuan and Huang, Liang and Liang, Chunyu and Kou, Lei},
  title = {Seismic Response Analysis of Dual-Chamber Aqueduct Structure with Fluid–Structure Interaction Based on CC-SFSM},
  journal = {International Journal of Computational Methods},
  year = {2026},
  volume = {23},
  number = {08},
  doi = {10.1142/s0219876226500210}
}
Kostenlos starten →