EUVIMEDEUVIMED entdecken
Crossref

When pipelines run but coordinates fail: A simple spatial specificity check for false locality in post-GWAS analysis

Zheng Han iD, Hongcheng Zhu, Changzai Li

Journal of Bioinformatics and Computational Biology · 2026-06 · 24 (03)

DOI: 10.1142/s0219720026710034 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of Bioinformatics and Computational Biology, online erschienen am 18.06.2026. Verfasst von Zheng Han und 2 weiteren Autor:innen. Beteiligte Einrichtung: Graduate School of North China University of Science and Technology, Tangshan, Hebei, P. R. China. Hauptthemen laut MEDLINE: Software, Genome-Wide Association Study. Die Arbeit nennt 25 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Some post-GWAS analysis software can run to completion without reporting an error while producing results that are not biologically valid. We call this failure false locality: a result appears to be local to a gene or protein because it was produced from a regional window, but the window or its metadata points to the wrong genomic address. We identify three mechanisms. First, a genome-build address mismatch occurs when GRCh38 protein-QTL coordinates are used with GRCh37 outcome files; in our 91-sentinel audit, 66 coordinates moved by more than 100[Formula: see text]kb and 54 moved by more than 200[Formula: see text]kb after remapping. Second, non-specific regional noise occurs when significant P values persist after the analysis window is deliberately moved to a zero-overlap variant set. Third, location-label blindness occurs when software returns the same output after the declared coordinate label is changed while the SNP table is unchanged; in an official SMR/HEIDI CXCL10 test, the top SNP, SMR P value, and HEIDI P value remained identical across correct, wrong, and shifted labels. We propose a simple Change Test: a result should not be treated as local evidence unless the numerical output changes, weakens, or disappears when the analysis window or coordinate label is intentionally moved to a biologically wrong location. This standard turns software execution from a passive success signal into an explicit spatial-specificity check.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SoftwareGenome-Wide Association StudyPolymorphism, Single NucleotideHumans

Stichwörter der Autor:innen

False localityGRCh37GRCh38Mendelian randomizationSMRgenome buildpQTLspatial specificitysummary statistics

Autor:innen und Institutionen

  • Graduate School of North China University of Science and Technology, Tangshan, Hebei, P. R. China.
  • Department of Thyroid Surgery, Affiliated Hospital of North China University of Science and Technology, 73 Jianshe South Road, Tangshan 063000, Hebei, P. R. China.

ORCID-Profile: Zheng Han

Zitieren

APA

Han, Z., Zhu, H., & Li, C. (2026). When pipelines run but coordinates fail: A simple spatial specificity check for false locality in post-GWAS analysis. Journal of Bioinformatics and Computational Biology, 24(03). https://doi.org/10.1142/s0219720026710034

Vancouver

Han Z, Zhu H, Li C. When pipelines run but coordinates fail: A simple spatial specificity check for false locality in post-GWAS analysis. Journal of Bioinformatics and Computational Biology. 2026;24(03). doi:10.1142/s0219720026710034

BibTeX
@article{Han2026,
  author = {Han, Zheng and Zhu, Hongcheng and Li, Changzai},
  title = {When pipelines run but coordinates fail: A simple spatial specificity check for false locality in post-GWAS analysis},
  journal = {Journal of Bioinformatics and Computational Biology},
  year = {2026},
  volume = {24},
  number = {03},
  doi = {10.1142/s0219720026710034}
}
Kostenlos starten →