Prediction of Drafted-Triathlon Race Time From Submaximal Laboratory Testing in Elite Triathletes
Canadian Journal of Applied Physiology · 01.08.2003 · 28 (4) · 547-560
DOI: 10.1139/h03-042 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Journal of Applied Physiology, erschienen am 01.08.2003. Verfasst von Olivier Hue. Beteiligte Einrichtung: Laboratoire ACTES; UPRES-EA 35-96, UFR-STAPS Université Antilles-Guyane, Campus de Fouillole, 97159 Pointe à Pitre Cedex, Guadeloupe, FWI. Hauptthemen laut MEDLINE: Bicycling, Clinical Laboratory Techniques, Running, Swimming. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 31 Literaturangaben.
Abstract (Originalsprache)
Purpose and methods: To determine which physiological variables accurately predict the race time of an Olympic-distance International Triathlon undertaken in drafted conditions, 8 elite triathletes underwent both maximal and submaximal laboratory and field physiological testing: a 400-m maximal swim test; an incremental treadmill test; an incremental cycling test; 30 min of cycling followed by 20 min of running (C-R); and 20 min of control running (R) at the exact same speed variations as in running in C-R. Blood samples were drawn to measure venous lactate concentration after the 400-m swim and the cycle and run segments of C-R. During the maximal cycling and running exercises, data were collected using an automated breath-by-breath system.
Results
The only parameters correlated with the overall drafted-triathlon time were lactate concentration noted at the end of the cycle segment (r = 0.83, p < 0. 05) and the distance covered during the running part of the submaximal C-R test (r = -0.92, p < 0.01). Stepwise multiple regression analysis revealed a highly significant (r = 0.96, p < 0.02) relationship between predicted race time (from laboratory measures) and actual race time, using the following calculation: Predicted Triathlon Time (s) = -1.128 (distance covered during R of C-R [m]) + 38.8 ([lactate] at the end of C in C-R) + 13,338. The high R 2 value of 0.93 indicated that, taken together, these two laboratory measures could account for 93% of the variance in race times during a drafted triathlon.
Conclusion
Complementing previous studies, this study demonstrates that different parameters seem to be reliable for predicting performance in drafted vs. nondrafted Olympic-triathlon races. It also demonstrates that, for elite triathletes competing in a drafted Olympic-distance triathlon, performance is accurately predicted from the results of submaximal laboratory measures. Key words: swimming, cycling, running, lactate, oxygen uptake
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Laboratoire ACTES; UPRES-EA 35-96, UFR-STAPS Université Antilles-Guyane, Campus de Fouillole, 97159 Pointe à Pitre Cedex, Guadeloupe, FWI.
Zitieren
APA
Hue, O. (2003). Prediction of Drafted-Triathlon Race Time From Submaximal Laboratory Testing in Elite Triathletes. Canadian Journal of Applied Physiology, 28(4), 547-560. https://doi.org/10.1139/h03-042
Vancouver
Hue O. Prediction of Drafted-Triathlon Race Time From Submaximal Laboratory Testing in Elite Triathletes. Canadian Journal of Applied Physiology. 2003;28(4):547-560. doi:10.1139/h03-042
BibTeX
@article{Hue2003,
author = {Hue, Olivier},
title = {Prediction of Drafted-Triathlon Race Time From Submaximal Laboratory Testing in Elite Triathletes},
journal = {Canadian Journal of Applied Physiology},
year = {2003},
volume = {28},
number = {4},
pages = {547--560},
doi = {10.1139/h03-042}
}
EUVIMED