Comparison of extracellular vesicle elution methods from aptamer-conjugated magnetic beads for downstream physical characterization and immunoassays
Canadian Journal of Chemistry · 01.10.2026 · 104 (10) · 886-894
DOI: 10.1139/cjc-2025-0084 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Journal of Chemistry, erschienen am 01.10.2026. Verfasst von Lian Miller und 3 weiteren Autor:innen. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 56 Literaturangaben. Gefördert von: University of Guelph, Natural Sciences and Engineering Research Council of Canada.
Abstract (Originalsprache)
Aptamer-based affinity chromatography is a promising approach for the efficient capture and gentle release of extracellular vesicles (EVs) with preserved EV integrity; however, to date, there is no direct comparison of EV elution methods from the aptamers and evaluation of their effects on downstream EV analysis. This study compares the efficacy of two simple-to-implement elution methods using deoxyribonuclease (DNase) I and NaCl in releasing EVs from anti-CD63-aptamer-conjugated magnetic beads, focusing on downstream physical and protein analysis of the EVs. We used anti-CD63-aptamer-functionalized magnetic beads to capture EVs from ovarian cancer cell line OVCAR-3 culture media, subsequently eluting them using NaCl (0.5 or 1.0 M) or DNase I (50 or 100 U/mL). Dynamic light scattering and transmission electron microscopy (TEM) were used to assess elution efficiency and EV morphology, respectively, and showed intact EVs after elution. Enzyme-linked immunosorbent assay (ELISA) quantified CD9 and EGFR protein expression in the eluted EVs. Our results indicated that NaCl and DNase I can effectively elute EVs, maintaining their structural integrity as observed by TEM. 100 U/mL DNase I provided the highest elution efficiency of 88%, followed closely by 1.0 M NaCl with a comparable efficiency of 87%. With ELISA targeting two EV surface proteins, CD9 and EGFR, EVs eluted by 1.0 M NaCl demonstrated the highest signals for both proteins. Due to the high elution efficiency and low cost of NaCl, it is more suitable for immunoassay-based downstream analysis. This comparative study demonstrated the importance of selecting an appropriate elution method to optimize EV yield and maintain protein activity for downstream applications.
Förderung
- University of Guelph
- Natural Sciences and Engineering Research Council of Canada
Zitieren
APA
Miller, L., Goodrum, R., Ströhle, G., & Li, H. (2026). Comparison of extracellular vesicle elution methods from aptamer-conjugated magnetic beads for downstream physical characterization and immunoassays. Canadian Journal of Chemistry, 104(10), 886-894. https://doi.org/10.1139/cjc-2025-0084
Vancouver
Miller L, Goodrum R, Ströhle G, Li H. Comparison of extracellular vesicle elution methods from aptamer-conjugated magnetic beads for downstream physical characterization and immunoassays. Canadian Journal of Chemistry. 2026;104(10):886-894. doi:10.1139/cjc-2025-0084
BibTeX
@article{Miller2026,
author = {Miller, Lian and Goodrum, Rebecca and Ströhle, Gisela and Li, Huiyan},
title = {Comparison of extracellular vesicle elution methods from aptamer-conjugated magnetic beads for downstream physical characterization and immunoassays},