Experimental Investigation of Suction Installation Behavior of Caissons in Loose Saturated Sands
Canadian Geotechnical Journal · 19.06.2025
DOI: 10.1139/cgj-2025-0073 ↗Kurz gefasst
Fachartikel in der Zeitschrift Canadian Geotechnical Journal, online erschienen am 19.06.2025. Verfasst von Bilal Ahmad Malik und 4 weiteren Autor:innen. Die Arbeit wurde bisher 13-mal zitiert (Crossref).
Abstract (Originalsprache)
With the continuous expansion of global offshore wind power, suction caissons are increasingly becoming a significant foundation form due to their advantages such as low installation noise, convenient construction, and reusability. However, localized seepage induced soil disturbance and strength changes during their installation remain underexplored, leading to uncertainties in their capacity assessment. This paper presents a series of experimental investigations in loose saturated sand, comparing suction and embedded installations for caissons with varying length-to-diameter (L/D) ratios coupled with Cone Penetration Tests (CPT) to evaluate soil strength changes inside and outside the caissons. For both installations, the results reveal similar lateral load-bearing capacities (0.12 kN) for shorter caissons (L = 120 mm), whereas for longer suction installed caissons (L = 240 mm), the capacity was reduced by approximately 80%, due to internal soil weakening and an upward shift of the rotation centre. CPT data further revealed compaction enhancement outside and seepage-induced reduction in soil strength inside the caisson, jointly affecting failure behavior. Based on these findings, the conventional bearing capacity formula for fully embedded caissons was modified to account for partial embedment and external-internal soil strength differences, and a novel mechanically-derived failure criterion was proposed, accurately capturing non-linear load responses and improving prediction of suction caisson capacity for various load eccentricities and L/D ratios, thus supporting optimized offshore foundation design.
Zitieren
APA
Malik, B. A., Jie, S., Zeyu, L., Ouyang, Z., & Wang, D. (2025). Experimental Investigation of Suction Installation Behavior of Caissons in Loose Saturated Sands. Canadian Geotechnical Journal. https://doi.org/10.1139/cgj-2025-0073
Vancouver
Malik BA, Jie S, Zeyu L, Ouyang Z, Wang D. Experimental Investigation of Suction Installation Behavior of Caissons in Loose Saturated Sands. Canadian Geotechnical Journal. 2025. doi:10.1139/cgj-2025-0073
BibTeX
@article{Malik2025,
author = {Malik, Bilal Ahmad and Jie, Shi and Zeyu, Liang and Ouyang, Zhongkun and Wang, Dong},
title = {Experimental Investigation of Suction Installation Behavior of Caissons in Loose Saturated Sands},
journal = {Canadian Geotechnical Journal},
year = {2025},
doi = {10.1139/cgj-2025-0073}
}