EUVIMEDEUVIMED entdecken
Crossref

Evaluating Cooling-Center Coverage Using Persistent Homology of a Filtered Witness Complex

Erin O’Neil, Sarah Tymochko

SIAM Journal on Applied Mathematics · 31.08.2026 · 86 (4) · 2148-2171

DOI: 10.1137/25m1741145 ↗

Kurz gefasst

Fachartikel in der Zeitschrift SIAM Journal on Applied Mathematics, online erschienen am 13.08.2026. Verfasst von Erin O’Neil und 1 weiteren Autor:innen. Die Arbeit nennt 43 Literaturangaben. Gefördert von: UCLA’s Queen’s Road Foundation.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In light of the increase in frequency of extreme heat events, there is a critical need to develop tools to identify geographic locations that are at risk of heat-related mortality. This paper aims to identify locations by assessing holes in cooling-center coverage using persistent homology (PH), a method from topological data analysis (TDA). Persistent homology has shown promising results in identifying holes in coverage of specific resources. We adapt these methods using a witness complex construction to study the coverage of cooling centers. We test our approach on four locations (central Boston, MA; central Austin, TX; Portland, OR; and Miami, FL) and use death times, a measurement of the size and scale of the gap in coverage, to identify most at risk regions. For comparison, we implement a standard technique for studying the risk of heat-related mortality called a heat vulnerability index (HVI). The HVI is a numerical score calculated for a geographic area based on demographic information. PH and the HVI identify different locations as vulnerable, thus indicating a potential value of assessing vulnerability from multiple perspectives. By using the regions identified by both persistent homology and the HVI, we provide a more holistic understanding of coverage.

Förderung

  • UCLA’s Queen’s Road Foundation

Zitieren

APA

O’Neil, E., & Tymochko, S. (2026). Evaluating Cooling-Center Coverage Using Persistent Homology of a Filtered Witness Complex. SIAM Journal on Applied Mathematics, 86(4), 2148-2171. https://doi.org/10.1137/25m1741145

Vancouver

O’Neil E, Tymochko S. Evaluating Cooling-Center Coverage Using Persistent Homology of a Filtered Witness Complex. SIAM Journal on Applied Mathematics. 2026;86(4):2148-2171. doi:10.1137/25m1741145

BibTeX
@article{ONeil2026,
  author = {O’Neil, Erin and Tymochko, Sarah},
  title = {Evaluating Cooling-Center Coverage Using Persistent Homology of a Filtered Witness Complex},
  journal = {SIAM Journal on Applied Mathematics},
  year = {2026},
  volume = {86},
  number = {4},
  pages = {2148--2171},
  doi = {10.1137/25m1741145}
}
Kostenlos starten →