AFIRE: Accurate and Fast Image REconstruction Algorithm for Geometric-Inconsistent Multispectral CT
SIAM Journal on Imaging Sciences · 30.09.2026 · 19 (3) · 1745-1779
DOI: 10.1137/24m1711467 ↗Kurz gefasst
Fachartikel in der Zeitschrift SIAM Journal on Imaging Sciences, online erschienen am 10.08.2026. Verfasst von Yu Gao und 1 weiteren Autor:innen. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 41 Literaturangaben. Gefördert von: National Natural Science Foundation of China, National Key Research & Development Program of China.
Abstract (Originalsprache)
For nonlinear multispectral computed tomography (CT), accurate and fast image reconstruction is challenging when the scanning geometric parameters under different X-ray energy spectra are inconsistent or mismatched. Motivated by this, we propose an Accurate and Fast Image REconstruction (AFIRE) algorithm to address such problems in the case of a mildly full scan. From the continuous (resp., discrete) setting, we discover that the derivative operator (gradient) of the involved nonlinear mapping at some special points, for example, at zero, can be represented as a composition (block multiplication) of a diagonal operator (matrix) composed of X-ray transforms (projection matrices) and a very small-scale matrix. Based on these insights, the AFIRE algorithm is proposed by leveraging the simplified Newton method. Under proper conditions, we establish the convergence theory of the proposed algorithm. Furthermore, numerical experiments are also carried out to verify that the proposed algorithm can accurately and effectively reconstruct the basis images in completely geometric-inconsistent dual-energy CT with noiseless and noisy projection data. Particularly, the proposed algorithm significantly outperforms some state-of-the-art methods in terms of accuracy and efficiency. Finally, the flexibility and extensibility of the proposed algorithm are also demonstrated.
Förderung
- National Natural Science Foundation of China
- National Key Research & Development Program of China
Zitieren
APA
Gao, Y., & Chen, C. (2026). AFIRE: Accurate and Fast Image REconstruction Algorithm for Geometric-Inconsistent Multispectral CT. SIAM Journal on Imaging Sciences, 19(3), 1745-1779. https://doi.org/10.1137/24m1711467
Vancouver
Gao Y, Chen C. AFIRE: Accurate and Fast Image REconstruction Algorithm for Geometric-Inconsistent Multispectral CT. SIAM Journal on Imaging Sciences. 2026;19(3):1745-1779. doi:10.1137/24m1711467
BibTeX
@article{Gao2026,
author = {Gao, Yu and Chen, Chong},
title = {AFIRE: Accurate and Fast Image REconstruction Algorithm for Geometric-Inconsistent Multispectral CT},
journal = {SIAM Journal on Imaging Sciences},
year = {2026},
volume = {19},
number = {3},
pages = {1745--1779},
doi = {10.1137/24m1711467}
}
EUVIMED