Validation of a novel point-of-care ultrasound method to assess diaphragmatic excursion
Regional Anesthesia & Pain Medicine · 2024
DOI: 10.1136/rapm-2023-104983 ↗Kurz gefasst
Validierungsstudie in der Zeitschrift Regional Anesthesia & Pain Medicine, 2024. Verfasst von Diogo Da Conceicao und 7 weiteren Autor:innen. Beteiligte Einrichtung: Anesthesia and Pain Management, Toronto Western Hospital - University Health Network, Toronto, Ontario, Canada. Hauptthemen laut MEDLINE: Diaphragm, Point-of-Care Systems, Ultrasonography. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 14 Literaturangaben.
Abstract (Originalsprache)
Introduction
Point-of-care ultrasound can assess diaphragmatic function and rule in or rule out paresis of the diaphragm. While this is a useful bedside tool, established methods have significant limitations. This study explores a new method to assess diaphragmatic motion by measuring the excursion of the uppermost point of the zone of apposition (ZOA) at the mid-axillary line using a high-frequency linear ultrasound probe and compares it with two previously established methods: the assessment of the excursion of the dome of the diaphragm (DOD) and the thickening ratio at the ZOA.
Methods
This is a single-centre, prospective comparative study on elective surgical patients with normal diaphragmatic function. Following research ethics board approval and patient written consent, 75 elective surgical patients with normal diaphragmatic function were evaluated preoperatively. Three ultrasound methods were compared: (1) assessment of the excursion of the DOD using a curvilinear probe through an abdominal window; (2) assessment of the thickening fraction of the ZOA; and (3) assessment of the excursion of the ZOA. The last two methods performed with a linear probe on the lateral aspect of the chest.
Results
Seventy-five patients were studied. We found that the evaluation of the excursion of the ZOA was more consistently successful (100% bilaterally) than the evaluation of the excursion of the DOD (98.7% and 34.7% on the right and left sides, respectively). The absolute values of the excursion of the ZOA were greater than and well correlated with the values of the DOD.
Conclusion
Our preliminary data from this exploratory study suggest that the evaluation of the excursion of the ZOA on the lateral aspect of the chest using a linear probe is consistently successful on both right and left sides. Future studies are needed to establish the distribution of normal values and suggest diagnostic criteria for diaphragmatic paresis or paralysis. Trial registration number NCT03225508 .
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Anesthesia and Pain Management, Toronto Western Hospital - University Health Network, Toronto, Ontario, Canada.
- Anesthesia and Pain Management, Toronto Western Hospital - University Health Network, Toronto, Ontario, Canada anahi.perlas@uhn.ca.
- Biostatistical Research Unit, University Health Network, Toronto, Ontario, Canada.
ORCID-Profile: Anahi Perlas
Zitieren
APA
Da Conceicao, D., Perlas, A., Giron Arango, L., Wild, K., Li, Q., Huszti, E., Chowdhury, J., & Chan, V. (2024). Validation of a novel point-of-care ultrasound method to assess diaphragmatic excursion. Regional Anesthesia & Pain Medicine. https://doi.org/10.1136/rapm-2023-104983
Vancouver
Da Conceicao D, Perlas A, Giron Arango L, Wild K, Li Q, Huszti E, et al. Validation of a novel point-of-care ultrasound method to assess diaphragmatic excursion. Regional Anesthesia & Pain Medicine. 2024. doi:10.1136/rapm-2023-104983
BibTeX
@article{DaConceicao2024,
author = {Da Conceicao, Diogo and Perlas, Anahi and Giron Arango, Laura and Wild, Kim and Li, Qixuan and Huszti, Ella and Chowdhury, Jayanta and Chan, Vincent},
title = {Validation of a novel point-of-care ultrasound method to assess diaphragmatic excursion},
journal = {Regional Anesthesia & Pain Medicine},
year = {2024},
doi = {10.1136/rapm-2023-104983}
}
EUVIMED