EUVIMEDEUVIMED entdecken
Crossref

Safe use of fluorinated gases in vitreoretinal surgery: learning from patient safety incidents with expert panel recommendations from the British and Eire Association of Vitreoretinal Surgeons (BEAVRS)

Fernando J Huelin, Peter Kiraly, George Moussa, Laura Wakely, James E Neffendorf, Louisa Wickham, Eoin O'Sullivan, Anna Grabowska, David H W Steel, Assad Jalil, BEAVRS board, on behalf ofBEAVRS board

British Journal of Ophthalmology · 06.07.2026 · bjo-2026-329908

DOI: 10.1136/bjo-2026-329908 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, online erschienen am 06.07.2026. Verfasst von Fernando J Huelin und 11 weiteren Autor:innen. Beteiligte Einrichtung: Manchester Royal Eye Hospital, Manchester University Hospitals NHS Foundation Trust, Manchester, UK. Die Arbeit nennt 41 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Errors in intravitreal fluorinated gas selection or dilution can result in unintended expansile concentrations, causing irreversible visual loss. We aimed to quantify the problem using national incident reporting, published literature and a UK surgeon survey, developing expert consensus recommendations on safe storage, handling and intraocular use.

Methods

NHS England patient safety incident repositories (National Reporting and Learning System and Learn from Patient Safety Events) were searched for events related to intravitreal gas use (2010–2025), followed by thematic analysis. A targeted literature review identified sight-threatening complications associated with incorrect gas concentration. In parallel, a national survey of the British and Eire Association of Vitreoretinal Surgeons (BEAVRS) assessed preparation practices, complications, management strategies, storage and environmental considerations. An expert panel synthesised findings into consensus recommendations.

Results

National reporting identified 47 relevant incidents; 29 cases involved incorrect gas concentration due to preparation errors. 14 cases resulted in at least moderate harm, including eight with blindness or severe visual impairment; pure gas concentration (100%) administration was documented in six cases. The literature review identified 20 severe cases across 11 publications. Among 108 BEAVRS respondents, 38.9% recalled at least one significant complication related to incorrect gas concentration; 16.7% reported witnessing sight-threatening outcomes, most commonly central retinal artery occlusion. Recommendations focused on clear labelling/colour coding, standardised dilution protocols, staff training, mandatory two-person checks, appropriate use and segregation of pre-mixed iso-expansile gases and adjunctive safety measures (gas cards/wristbands).

Conclusion

Incorrect intraocular gas concentration is likely under-reported but can cause devastating, preventable harm. Standardised systems for storage, preparation, verification and postoperative review may reduce risk while supporting environmentally responsible practice.

Schlagwörter

Stichwörter der Autor:innen

Intraocular pressureOphthalmologic Surgical ProceduresSurgeonsSurveys and QuestionnairesVitreous

Autor:innen und Institutionen

  • Manchester Royal Eye Hospital, Manchester University Hospitals NHS Foundation Trust, Manchester, UK.
  • Nuffield Laboratory of Ophthalmology, University of Oxford, Oxford, UK.
  • Ophthalmology, York and Scarborough Teaching Hospitals NHS Foundation Trust, York, UK.
  • Ophthalmology, King's College Hospital NHS Foundation Trust, London, UK.
  • Moorfields Eye Hospital NHS Foundation Trust, London, UK.
  • Sunderland Eye Infirmary, Sunderland, UK.

Zitieren

APA

Huelin, F. J., Kiraly, P., Moussa, G., Wakely, L., Neffendorf, J. E., Wickham, L., O'Sullivan, E., Grabowska, A., Steel, D. H. W., Jalil, A., BEAVRS board, & on behalf ofBEAVRS board (2026). Safe use of fluorinated gases in vitreoretinal surgery: learning from patient safety incidents with expert panel recommendations from the British and Eire Association of Vitreoretinal Surgeons (BEAVRS). British Journal of Ophthalmology, bjo-2026-329908. https://doi.org/10.1136/bjo-2026-329908

Vancouver

Huelin FJ, Kiraly P, Moussa G, Wakely L, Neffendorf JE, Wickham L, et al. Safe use of fluorinated gases in vitreoretinal surgery: learning from patient safety incidents with expert panel recommendations from the British and Eire Association of Vitreoretinal Surgeons (BEAVRS). British Journal of Ophthalmology. 2026:bjo-2026-329908. doi:10.1136/bjo-2026-329908

BibTeX
@article{Huelin2026,
  author = {Huelin, Fernando J and Kiraly, Peter and Moussa, George and Wakely, Laura and Neffendorf, James E and Wickham, Louisa and O'Sullivan, Eoin and Grabowska, Anna and Steel, David H W and Jalil, Assad and BEAVRS board, BEAVRS board and on behalf ofBEAVRS board, on behalf ofBEAVRS board},
  title = {Safe use of fluorinated gases in vitreoretinal surgery: learning from patient safety incidents with expert panel recommendations from the British and Eire Association of Vitreoretinal Surgeons (BEAVRS)},
  journal = {British Journal of Ophthalmology},
  year = {2026},
  pages = {bjo--2026--329908},
  doi = {10.1136/bjo-2026-329908}
}
Kostenlos starten →