Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults
British Journal of Ophthalmology · 05.06.2026 · bjo-2025-329013
DOI: 10.1136/bjo-2025-329013 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Ophthalmology, online erschienen am 05.06.2026. Verfasst von Jinyi Jia und 6 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and S…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Science & Technology Development Fund of Tianjin Education Commission for Higher Education.
Abstract (Originalsprache)
Purpose
To evaluate the repeatability of the adaptive optics scanning laser ophthalmoscopy (AO-SLO) system (Mona II) in measuring cone photoreceptor parameters and compare repeatability differences in different retinal regions.
Methods
A total of 126 healthy adults aged between 18 and 36 years with cycloplegic spherical equivalent refraction ≤+0.50 D and >−6.00 D were enrolled. Retinal images were captured at the macular fovea centre (0°, 0°), the temporal, nasal, superior and inferior regions at 1.5° and 3.0° eccentricity. At each region, multiple 2.4°×2.4° images were sequentially captured with 0.9°×2.4° overlap between adjacent regions, covering the detection area within 4.2° centred on the fovea. Three images with clear cone photoreceptors and image quality scores of 0.8 or above were selected from each region for analysis.
Results
All parameters of the cone photoreceptors demonstrated excellent repeatability, with intraclass correlation coefficient (ICC) ranging from 0.967 to 0.994. The cone density exhibited good repeatability, with the fovea and the nasal region at 1.5° eccentricity showing the highest ICC (0.992). For the cone spacing, regularity and dispersion also demonstrated high repeatability across all regions (all ICC >0.90).
Conclusions
The Mona II AO-SLO system showed high repeatability in measuring parameters of cone photoreceptors in healthy adults, with consistent performance across retinal area within a 4.2° range. Trial registration number ChiCTR2500114249.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin,…
Förderung
- Science & Technology Development Fund of Tianjin Education Commission for Higher Education
Zitieren
APA
Jia, J., Du, B., Rong, H., Wang, B., Pazo, E. E., Liu, G., & Wei, R. (2026). Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults. British Journal of Ophthalmology, bjo-2025-329013. https://doi.org/10.1136/bjo-2025-329013
Vancouver
Jia J, Du B, Rong H, Wang B, Pazo EE, Liu G, et al. Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults. British Journal of Ophthalmology. 2026:bjo-2025-329013. doi:10.1136/bjo-2025-329013
BibTeX
@article{Jia2026,
author = {Jia, Jinyi and Du, Bei and Rong, Hua and Wang, Biying and Pazo, Emmanuel Eric and Liu, Guihua and Wei, Ruihua},
title = {Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults},
journal = {British Journal of Ophthalmology},
year = {2026},
pages = {bjo--2025--329013},
doi = {10.1136/bjo-2025-329013}
}
EUVIMED