EUVIMEDEUVIMED entdecken
Crossref

Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults

Jinyi Jia, Bei Du, Hua Rong, Biying Wang, Emmanuel Eric Pazo, Guihua Liu, Ruihua Wei

British Journal of Ophthalmology · 05.06.2026 · bjo-2025-329013

DOI: 10.1136/bjo-2025-329013 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, online erschienen am 05.06.2026. Verfasst von Jinyi Jia und 6 weiteren Autor:innen. Beteiligte Einrichtung: Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and S…. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 25 Literaturangaben. Gefördert von: Science & Technology Development Fund of Tianjin Education Commission for Higher Education.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To evaluate the repeatability of the adaptive optics scanning laser ophthalmoscopy (AO-SLO) system (Mona II) in measuring cone photoreceptor parameters and compare repeatability differences in different retinal regions.

Methods

A total of 126 healthy adults aged between 18 and 36 years with cycloplegic spherical equivalent refraction ≤+0.50 D and >−6.00 D were enrolled. Retinal images were captured at the macular fovea centre (0°, 0°), the temporal, nasal, superior and inferior regions at 1.5° and 3.0° eccentricity. At each region, multiple 2.4°×2.4° images were sequentially captured with 0.9°×2.4° overlap between adjacent regions, covering the detection area within 4.2° centred on the fovea. Three images with clear cone photoreceptors and image quality scores of 0.8 or above were selected from each region for analysis.

Results

All parameters of the cone photoreceptors demonstrated excellent repeatability, with intraclass correlation coefficient (ICC) ranging from 0.967 to 0.994. The cone density exhibited good repeatability, with the fovea and the nasal region at 1.5° eccentricity showing the highest ICC (0.992). For the cone spacing, regularity and dispersion also demonstrated high repeatability across all regions (all ICC >0.90).

Conclusions

The Mona II AO-SLO system showed high repeatability in measuring parameters of cone photoreceptors in healthy adults, with consistent performance across retinal area within a 4.2° range. Trial registration number ChiCTR2500114249.

Schlagwörter

Stichwörter der Autor:innen

Cell CountImagingRetina

Autor:innen und Institutionen

  • Tianjin Key Laboratory of Retinal Functions and Diseases, Tianjin Branch of National Clinical Research Center for Ocular Disease, Eye Institute and School of Optometry, Tianjin Medical University Eye Hospital, Tianjin,…

Förderung

  • Science & Technology Development Fund of Tianjin Education Commission for Higher Education

Zitieren

APA

Jia, J., Du, B., Rong, H., Wang, B., Pazo, E. E., Liu, G., & Wei, R. (2026). Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults. British Journal of Ophthalmology, bjo-2025-329013. https://doi.org/10.1136/bjo-2025-329013

Vancouver

Jia J, Du B, Rong H, Wang B, Pazo EE, Liu G, et al. Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults. British Journal of Ophthalmology. 2026:bjo-2025-329013. doi:10.1136/bjo-2025-329013

BibTeX
@article{Jia2026,
  author = {Jia, Jinyi and Du, Bei and Rong, Hua and Wang, Biying and Pazo, Emmanuel Eric and Liu, Guihua and Wei, Ruihua},
  title = {Repeatability of cone photoreceptor metrics with a commercial adaptive optics scanning laser ophthalmoscopy (Mona II) in healthy adults},
  journal = {British Journal of Ophthalmology},
  year = {2026},
  pages = {bjo--2025--329013},
  doi = {10.1136/bjo-2025-329013}
}
Kostenlos starten →