Cutting without a blade: a clinical review of hypersonic vitrectomy
British Journal of Ophthalmology · 2026
DOI: 10.1136/bjo-2025-328693 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift British Journal of Ophthalmology, 2026. Verfasst von Siddharth Gandhi und 2 weiteren Autor:innen. Beteiligte Einrichtung: Queen's University School of Medicine, Kingston, Ontario, Canada parnian.arjmand@medportal.ca sid.gandhi@queensu.ca. Hauptthemen laut MEDLINE: Vitrectomy, Vitreous Body. Die Arbeit nennt 39 Literaturangaben.
Abstract (Originalsprache)
This review synthesises clinical evidence on hypersonic vitrectomy (HV), examining the gap between its theoretical advantages and observed performance. Originally proposed to reduce vitreoretinal traction and deliver smoother fluidics, HV has achieved successful vitreous removal in human studies, with surgeons reporting favourable qualitative handling. However, comparative trials have yielded mixed results for surgical efficiency versus contemporary pneumatic guillotine vitrectors. Prospective series also describe operational challenges, including intraoperative conversion to guillotine vitrectors in up to 30% of cases, often attributed to inconsistent vitreous liquefaction. Distinct safety considerations have been reported, most notably sclerotomy-site thermal injury and silicone oil emulsification. These findings underscore the difficulty of surpassing a rapidly evolving standard of care. Defining HV’s role in vitreoretinal surgery will require continued device refinements and adequately powered, multicentre comparative studies to determine where HV offers clear, reproducible benefits.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Queen's University School of Medicine, Kingston, Ontario, Canada parnian.arjmand@medportal.ca sid.gandhi@queensu.ca.
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada.
- Department of Ophthalmology and Vision Sciences, University of Toronto, Toronto, Ontario, Canada parnian.arjmand@medportal.ca sid.gandhi@queensu.ca.
- Mississauga Retina Institute, Mississauga, Ontario, Canada.
Zitieren
APA
Gandhi, S., Balas, M., & Arjmand, P. (2026). Cutting without a blade: a clinical review of hypersonic vitrectomy. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2025-328693
Vancouver
Gandhi S, Balas M, Arjmand P. Cutting without a blade: a clinical review of hypersonic vitrectomy. British Journal of Ophthalmology. 2026. doi:10.1136/bjo-2025-328693
BibTeX
@article{Gandhi2026,
author = {Gandhi, Siddharth and Balas, Michael and Arjmand, Parnian},
title = {Cutting without a blade: a clinical review of hypersonic vitrectomy},
journal = {British Journal of Ophthalmology},
year = {2026},
doi = {10.1136/bjo-2025-328693}
}