EUVIMEDEUVIMED entdecken
Crossref

Corneal endothelial cell density changes after Preserflo MicroShunt implantation

Taro Baba, Osamu Baba, Kikuno Hirose, Naoki Okada, Kana Tokumo, Hirokazu Sakaguchi, Kazuyuki Hirooka

British Journal of Ophthalmology · 2026

DOI: 10.1136/bjo-2025-328495 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, 2026. Verfasst von Taro Baba und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima, Japan. Hauptthemen laut MEDLINE: Endothelium, Corneal, Glaucoma Drainage Implants, Corneal Endothelial Cell Loss. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 22 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To evaluate the effect of Preserflo MicroShunt (PMS) implantation on corneal endothelial cell density (CECD) and to identify factors associated with CECD loss.

Methods

This retrospective study included patients who underwent PMS implantation, with or without combined cataract surgery, between March 2023 and April 2024, with a minimum of 12 months of postoperative follow-up. CECD was measured preoperatively and at 3, 6 and 12 months postoperatively. The primary outcome was the change in CECD after PMS implantation. Secondary analyses included linear regression to estimate annual CECD loss and logistic regression to identify factors associated with CECD reduction.

Results

In total, 104 eyes (70 PMS alone, 34 combined with phacoemulsification) were included. Mean CECD (cells/mm²) in PMS-alone group and combined-with-phacoemulsification group were 2312.9±501.7 and 2615.0±365.5 at baseline, 2253.7±530.9 and 2354.4±424.6 at 3 months postoperatively, 2234.6±528.5 and 2374.6±458.9 at 6 months postoperatively and 2149.2±537.5 and 2357.6±508.7 at 12 months postoperatively, respectively. The estimated annual CECD loss was 7.3±11.9% in the PMS-alone group and 8.0±17.2% in the combined-with-phacoemulsification group (p=0.47). Multivariate logistic regression revealed that a narrower tube–cornea angle (TCA) (p=0.01) and higher preoperative IOP (p=0.04) were significantly associated with greater CECD loss.

Conclusions

PMS implantation was associated with CECD reduction over 12 months. A narrower TCA and higher preoperative intraocular pressure were significant predictors of CECD loss.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Endothelium, CornealGlaucoma Drainage ImplantsCorneal Endothelial Cell LossHumansRetrospective StudiesIntraocular PressureFemaleMaleCell CountAgedVisual AcuityMiddle AgedPhacoemulsificationFollow-Up Studies

Stichwörter der Autor:innen

CorneaGlaucoma

Autor:innen und Institutionen

  • Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima, Japan.
  • Department of Ophthalmology and Visual Science, Hiroshima University, Hiroshima, Japan khirooka9@gmail.com.

Zitieren

APA

Baba, T., Baba, O., Hirose, K., Okada, N., Tokumo, K., Sakaguchi, H., & Hirooka, K. (2026). Corneal endothelial cell density changes after Preserflo MicroShunt implantation. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2025-328495

Vancouver

Baba T, Baba O, Hirose K, Okada N, Tokumo K, Sakaguchi H, et al. Corneal endothelial cell density changes after Preserflo MicroShunt implantation. British Journal of Ophthalmology. 2026. doi:10.1136/bjo-2025-328495

BibTeX
@article{Baba2026,
  author = {Baba, Taro and Baba, Osamu and Hirose, Kikuno and Okada, Naoki and Tokumo, Kana and Sakaguchi, Hirokazu and Hirooka, Kazuyuki},
  title = {Corneal endothelial cell density changes after Preserflo MicroShunt implantation},
  journal = {British Journal of Ophthalmology},
  year = {2026},
  doi = {10.1136/bjo-2025-328495}
}
Kostenlos starten →