EUVIMEDEUVIMED entdecken
Crossref

Multimodal artificial intelligence for retinal detachment diagnosis using fundus imaging and patient questionnaires

Naoyuki Yonemaru, Hitoshi Tabuchi, Hodaka Deguchi, Yuto Omi, Mao Tanabe, Naofumi Ishitobi, Hisashi Maruyama, Yuji Ayatsuka

British Journal of Ophthalmology · 2026-05 · 110 (5) · 586-591

DOI: 10.1136/bjo-2025-327506 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, online erschienen am 06.11.2025. Verfasst von Naoyuki Yonemaru und 7 weiteren Autor:innen. Beteiligte Einrichtung: Technology Laboratory, Cresco Ltd, Minato-ku, Tokyo, Japan n-yonemaru@cresco.co.jp. Hauptthemen laut MEDLINE: Retinal Detachment, Artificial Intelligence, Multimodal Imaging. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 21 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background/aims This study aimed to develop a multimodal artificial intelligence (AI) system that integrates fundus imaging and patient questionnaire data to achieve clinician-level diagnostic accuracy for diagnosing retinal detachment (RD).

Methods

Ultra-widefield fundus images and comprehensive patient questionnaires were collected from patients with RD and healthy controls at Tsukazaki Hospital. A multimodal model was developed using the Contrastive Language–Image Pretraining framework to classify RD cases, alongside separate image-only and questionnaire-only models for comparison. Per-image and per-subject analyses were conducted to assess model performance.

Results

The multimodal model outperformed single-modal models in per-image and per-subject assessments. It achieved accuracy, recall and F1 scores of 0.899±0.054, 0.902±0.043 and 0.902±0.048 in the per-image analysis and 0.893±0.071, 0.949±0.044 and 0.873±0.074 in the per-subject analysis, respectively. The AI model’s overall diagnostic accuracy was slightly lower than that of human clinicians; however, it exhibited a higher recall rate, indicating improved detection of true RD cases.

Conclusion

Integrating fundus imaging with patient questionnaire data significantly improves AI-based RD diagnosis. Future research needs to focus on expanding the dataset and refining the questionnaire design to further improve model performance.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Retinal DetachmentArtificial IntelligenceMultimodal ImagingHumansSurveys and QuestionnairesMaleFemaleFundus OculiMiddle AgedAdultAgedFluorescein Angiography

Stichwörter der Autor:innen

Retina

Autor:innen und Institutionen

  • Technology Laboratory, Cresco Ltd, Minato-ku, Tokyo, Japan n-yonemaru@cresco.co.jp.
  • Department of Ophthalmology, Tsukazaki Hosital, Himeji, Hyogo, Japan.
  • Department of Technology and Design Thinking for Medicine, Hiroshima University, Hiroshima, Hiroshima, Japan.
  • Department of Ophthalmology, Hyogo Medical University, Nishinomiya, Hyogo, Japan.
  • Technology Laboratory, Cresco Ltd, Minato-ku, Tokyo, Japan.

Zitieren

APA

Yonemaru, N., Tabuchi, H., Deguchi, H., Omi, Y., Tanabe, M., Ishitobi, N., Maruyama, H., & Ayatsuka, Y. (2026). Multimodal artificial intelligence for retinal detachment diagnosis using fundus imaging and patient questionnaires. British Journal of Ophthalmology, 110(5), 586-591. https://doi.org/10.1136/bjo-2025-327506

Vancouver

Yonemaru N, Tabuchi H, Deguchi H, Omi Y, Tanabe M, Ishitobi N, et al. Multimodal artificial intelligence for retinal detachment diagnosis using fundus imaging and patient questionnaires. British Journal of Ophthalmology. 2026;110(5):586-591. doi:10.1136/bjo-2025-327506

BibTeX
@article{Yonemaru2026,
  author = {Yonemaru, Naoyuki and Tabuchi, Hitoshi and Deguchi, Hodaka and Omi, Yuto and Tanabe, Mao and Ishitobi, Naofumi and Maruyama, Hisashi and Ayatsuka, Yuji},
  title = {Multimodal artificial intelligence for retinal detachment diagnosis using fundus imaging and patient questionnaires},
  journal = {British Journal of Ophthalmology},
  year = {2026},
  volume = {110},
  number = {5},
  pages = {586--591},
  doi = {10.1136/bjo-2025-327506}
}
Kostenlos starten →