An evaluation of approaches to imaging for the pre-surgical assessment of intraocular foreign body size
British Journal of Ophthalmology · 2025
DOI: 10.1136/bjo-2025-327245 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Ophthalmology, 2025. Verfasst von Kujani Wanniarachchi und 5 weiteren Autor:innen. Beteiligte Einrichtung: Vitreoretinal Research Group, University of Cambridge John van Geest Centre for Brain Repair, Cambridge, England, UK. Hauptthemen laut MEDLINE: Eye Foreign Bodies, Tomography, X-Ray Computed, Eye Injuries, Penetrating. Die Arbeit nennt 11 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
This study aims to assess the accuracy of CT imaging in estimating intraocular foreign body (IOFB) size by comparing pre-operative radiological measurements with post-surgical dimensions. A retrospective review of 12 cases over 9 years at a UK tertiary centre. IOFB size on CT imaging was compared with post-surgical measurements. Soft tissue window CT overestimated IOFB size (p=0.025). Bone window CT was more accurate but still varied, with one-third differing by>50% to definitive size. We conclude that caution is needed in CT-based IOFB size estimation. Plain radiographs may provide additional accuracy.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Vitreoretinal Research Group, University of Cambridge John van Geest Centre for Brain Repair, Cambridge, England, UK.
- Whipps Cross University Hospital NHS Trust, London, England, UK.
- Interventional neuroradiology department, National Hospital for Neurology and Neurosurgery, London, England, UK.
- Vitreoretinal Research Group, University of Cambridge John van Geest Centre for Brain Repair, Cambridge, England, UK mps34@cam.ac.uk.
Zitieren
APA
Wanniarachchi, K., Kaza, H., Safi, A., Ratneswaren, T., Poulson, A., & Snead, M. P. (2025). An evaluation of approaches to imaging for the pre-surgical assessment of intraocular foreign body size. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2025-327245
Vancouver
Wanniarachchi K, Kaza H, Safi A, Ratneswaren T, Poulson A, Snead MP. An evaluation of approaches to imaging for the pre-surgical assessment of intraocular foreign body size. British Journal of Ophthalmology. 2025. doi:10.1136/bjo-2025-327245
BibTeX
@article{Wanniarachchi2025,
author = {Wanniarachchi, Kujani and Kaza, Hrishikesh and Safi, Antoine and Ratneswaren, Tarini and Poulson, Arabella and Snead, Martin P},
title = {An evaluation of approaches to imaging for the pre-surgical assessment of intraocular foreign body size},
journal = {British Journal of Ophthalmology},
year = {2025},
doi = {10.1136/bjo-2025-327245}
}
EUVIMED