Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia

Kaiming Ruan, Dan Cheng, Yiyi Wang, Weihua Ni, Hongling Chen, Hao Chen, Shiqi Sun, Sen Lin, Aizhu Tao, Yilei Shao, Yufeng Ye, Meixiao Shen

British Journal of Ophthalmology · 2025

DOI: 10.1136/bjo-2025-327237 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, 2025. Verfasst von Kaiming Ruan und 11 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Wenzhou, People's Republic of…. Hauptthemen laut MEDLINE: Optic Disk, Microvessels, Retinal Vessels, Myopia, Degenerative. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Wenzhou Municipal Science and Technology Bureau.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To characterise microvasculature dropout (MvD) and assess the diagnostic efficacy of MvD in detecting glaucoma in eyes with high myopia (HM).

Methods

This prospective cross-sectional study included 107 participants divided into HM group and HM with glaucoma group. Structural and vascular parameters were quantified using swept-source optical coherence tomography (SS-OCT) and OCT angiography (OCTA), including the peripapillary retinal nerve fibre layer (pRNFL), macular ganglion cell inner plexiform layer (mGCIPL), superficial capillary plexus, radial peripapillary capillaries, optic disc microvasculature dropout (MvD-D) and peripapillary microvasculature dropout. Receiver operating characteristic curves were employed to evaluate the diagnostic performance of each parameter. Univariate and multivariate linear regression analyses were conducted to examine associations between these parameters and mean deviations of the visual field test.

Results

MvD-D outperformed all other structural and vascular metrics, achieving the highest area under the curve of 0.95. In multivariate regression analysis, MvD-D was identified as an independent factor associated with visual field loss (β=−0.42, p=0.02).

Conclusions

MvD-D demonstrates superior diagnostic performance compared with traditional structural markers such as pRNFL and mGCIPL in identifying glaucoma in highly myopic patients. Integrating MvD-D into routine clinical practice may provide a sightful value in detecting glaucoma with myopic discs.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Optic DiskMicrovesselsRetinal VesselsMyopia, DegenerativeGlaucomaHumansCross-Sectional StudiesFemaleMaleProspective StudiesTomography, Optical CoherenceVisual FieldsMiddle AgedRetinal Ganglion CellsNerve FibersIntraocular PressureAdultROC CurveVisual Field TestsFluorescein Angiography

Stichwörter der Autor:innen

Diagnostic tests/InvestigationGlaucoma

Autor:innen und Institutionen

  • National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Wenzhou, People's Republic of China.
  • National Clinical Research Center for Ocular Diseases, Eve Hospital, Wenzhou Medical University, Wenzhou, People's Republic of China.
  • Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, People's Republic of China.
  • National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Wenzhou, People's Republic of China smx77@mail.eye.ac.cn.

Förderung

  • National Natural Science Foundation of China
  • Wenzhou Municipal Science and Technology Bureau

Zitieren

APA

Ruan, K., Cheng, D., Wang, Y., Ni, W., Chen, H., Chen, H., Sun, S., Lin, S., Tao, A., Shao, Y., Ye, Y., & Shen, M. (2025). Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2025-327237

Vancouver

Ruan K, Cheng D, Wang Y, Ni W, Chen H, Chen H, et al. Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia. British Journal of Ophthalmology. 2025. doi:10.1136/bjo-2025-327237