Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia
British Journal of Ophthalmology · 2025
DOI: 10.1136/bjo-2025-327237 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Ophthalmology, 2025. Verfasst von Kaiming Ruan und 11 weiteren Autor:innen. Beteiligte Einrichtung: National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Wenzhou, People's Republic of…. Hauptthemen laut MEDLINE: Optic Disk, Microvessels, Retinal Vessels, Myopia, Degenerative. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 36 Literaturangaben. Gefördert von: National Natural Science Foundation of China, Wenzhou Municipal Science and Technology Bureau.
Abstract (Originalsprache)
Purpose
To characterise microvasculature dropout (MvD) and assess the diagnostic efficacy of MvD in detecting glaucoma in eyes with high myopia (HM).
Methods
This prospective cross-sectional study included 107 participants divided into HM group and HM with glaucoma group. Structural and vascular parameters were quantified using swept-source optical coherence tomography (SS-OCT) and OCT angiography (OCTA), including the peripapillary retinal nerve fibre layer (pRNFL), macular ganglion cell inner plexiform layer (mGCIPL), superficial capillary plexus, radial peripapillary capillaries, optic disc microvasculature dropout (MvD-D) and peripapillary microvasculature dropout. Receiver operating characteristic curves were employed to evaluate the diagnostic performance of each parameter. Univariate and multivariate linear regression analyses were conducted to examine associations between these parameters and mean deviations of the visual field test.
Results
MvD-D outperformed all other structural and vascular metrics, achieving the highest area under the curve of 0.95. In multivariate regression analysis, MvD-D was identified as an independent factor associated with visual field loss (β=−0.42, p=0.02).
Conclusions
MvD-D demonstrates superior diagnostic performance compared with traditional structural markers such as pRNFL and mGCIPL in identifying glaucoma in highly myopic patients. Integrating MvD-D into routine clinical practice may provide a sightful value in detecting glaucoma with myopic discs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Wenzhou, People's Republic of China.
- National Clinical Research Center for Ocular Diseases, Eve Hospital, Wenzhou Medical University, Wenzhou, People's Republic of China.
- Eye Hospital of Wenzhou Medical University Hangzhou Branch, Hangzhou, People's Republic of China.
- National Engineering Research Center of Ophthalmology and Optometry, Eye Hospital, Wenzhou Medical University, Wenzhou, Wenzhou, People's Republic of China smx77@mail.eye.ac.cn.
Förderung
- National Natural Science Foundation of China
- Wenzhou Municipal Science and Technology Bureau
Zitieren
APA
Ruan, K., Cheng, D., Wang, Y., Ni, W., Chen, H., Chen, H., Sun, S., Lin, S., Tao, A., Shao, Y., Ye, Y., & Shen, M. (2025). Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2025-327237
Vancouver
Ruan K, Cheng D, Wang Y, Ni W, Chen H, Chen H, et al. Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia. British Journal of Ophthalmology. 2025. doi:10.1136/bjo-2025-327237
BibTeX
@article{Ruan2025,
author = {Ruan, Kaiming and Cheng, Dan and Wang, Yiyi and Ni, Weihua and Chen, Hongling and Chen, Hao and Sun, Shiqi and Lin, Sen and Tao, Aizhu and Shao, Yilei and Ye, Yufeng and Shen, Meixiao},
title = {Diagnostic accuracy of optic disc microvasculature dropout for detecting glaucoma in eyes with high myopia},
journal = {British Journal of Ophthalmology},
year = {2025},
doi = {10.1136/bjo-2025-327237}
}
EUVIMED