Using artificial intelligence to improve human performance: efficient retinal disease detection training with synthetic images
British Journal of Ophthalmology · 2024
DOI: 10.1136/bjo-2023-324923 ↗Kurz gefasst
Fachartikel in der Zeitschrift British Journal of Ophthalmology, 2024. Verfasst von Hitoshi Tabuchi und 11 weiteren Autor:innen. Beteiligte Einrichtung: Department of Technology and Design Thinking for Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Hirosh…. Hauptthemen laut MEDLINE: Artificial Intelligence, Retinal Diseases, Ophthalmology. Die Arbeit wurde bisher 23-mal zitiert (Crossref) und nennt 26 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Artificial intelligence (AI) in medical imaging diagnostics has huge potential, but human judgement is still indispensable. We propose an AI-aided teaching method that leverages generative AI to train students on many images while preserving patient privacy.
Methods
A web-based course was designed using 600 synthetic ultra-widefield (UWF) retinal images to teach students to detect disease in these images. The images were generated by stable diffusion, a large generative foundation model, which we fine-tuned with 6285 real UWF images from six categories: five retinal diseases (age-related macular degeneration, glaucoma, diabetic retinopathy, retinal detachment and retinal vein occlusion) and normal. 161 trainee orthoptists took the course. They were evaluated with two tests: one consisting of UWF images and another of standard field (SF) images, which the students had not encountered in the course. Both tests contained 120 real patient images, 20 per category. The students took both tests once before and after training, with a cool-off period in between.
Results
On average, students completed the course in 53 min, significantly improving their diagnostic accuracy. For UWF images, student accuracy increased from 43.6% to 74.1% (p
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Technology and Design Thinking for Medicine, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Hiroshima, Japan htabuchi@hiroshima-u.ac.jp.
- Department of Ophthalmology, Tsukazaki Hospital, Himeji, Hyogo, Japan.
- Usher Institute,College of Medicine and Veterinary Medicine, The University of Edinburgh, Edinburgh, Scotland, UK.
- Department of Orthoptics and Visual Sciences, Niigata University of Health and Welfare, Niigata, Niigata, Japan.
- Department of Ophthalmology, Graduate School of Biomedical and Health Sciences, Hiroshima University, Hiroshima, Hiroshima, Japan.
- Bayes Centre, College of Science and Engineering, The University of Edinburgh, Edinburgh, Scotland, UK.
ORCID-Profile: Hitoshi Tabuchi, Justin Engelmann, Yoshiaki Kiuchi
Zitieren
APA
Tabuchi, H., Engelmann, J., Maeda, F., Nishikawa, R., Nagasawa, T., Yamauchi, T., Tanabe, M., Akada, M., Kihara, K., Nakae, Y., Kiuchi, Y., & Bernabeu, M. O. (2024). Using artificial intelligence to improve human performance: efficient retinal disease detection training with synthetic images. British Journal of Ophthalmology. https://doi.org/10.1136/bjo-2023-324923
Vancouver
Tabuchi H, Engelmann J, Maeda F, Nishikawa R, Nagasawa T, Yamauchi T, et al. Using artificial intelligence to improve human performance: efficient retinal disease detection training with synthetic images. British Journal of Ophthalmology. 2024. doi:10.1136/bjo-2023-324923
BibTeX
@article{Tabuchi2024,
author = {Tabuchi, Hitoshi and Engelmann, Justin and Maeda, Fumiatsu and Nishikawa, Ryo and Nagasawa, Toshihiko and Yamauchi, Tomofusa and Tanabe, Mao and Akada, Masahiro and Kihara, Keita and Nakae, Yasuyuki and Kiuchi, Yoshiaki and Bernabeu, Miguel O},
title = {Using artificial intelligence to improve human performance: efficient retinal disease detection training with synthetic images},
journal = {British Journal of Ophthalmology},
year = {2024},
doi = {10.1136/bjo-2023-324923}
}
EUVIMED