EUVIMEDEUVIMED entdecken
Crossref

Detecting the corneal neovascularisation area using artificial intelligence

Burak Mergen iD, Tarek Safi, Matthias Nadig, Gopal Bhattrai, Loay Daas, Jan Alexandersson, Berthold Seitz iD

British Journal of Ophthalmology · 2024-05 · 108 (5) · 667-672

DOI: 10.1136/bjo-2023-323308 ↗

Kurz gefasst

Fachartikel in der Zeitschrift British Journal of Ophthalmology, online erschienen am 20.06.2023. Verfasst von Burak Mergen und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Saarland University Medical Center (UKS), Homburg, Saarland, Germany burakmergen@gmail.com. Hauptthemen laut MEDLINE: Corneal Neovascularization, Artificial Intelligence, Algorithms. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 35 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Aims

To create and assess the performance of an artificial intelligence-based image analysis tool for the measurement and quantification of the corneal neovascularisation (CoNV) area.

Methods

Slit lamp images of patients with CoNV were exported from the electronic medical records and included in the study. An experienced ophthalmologist made manual annotations of the CoNV areas, which were then used to create, train and evaluate an automated image analysis tool that uses deep learning to segment and detect CoNV areas. A pretrained neural network (U-Net) was used and fine-tuned on the annotated images. Sixfold cross-validation was used to evaluate the performance of the algorithm on each subset of 20 images. The main metric for our evaluation was intersection over union (IoU).

Results

The slit lamp images of 120 eyes of 120 patients with CoNV were included in the analysis. Detections of the total corneal area achieved IoU between 90.0% and 95.5% in each fold and those of the non-vascularised area achieved IoU between 76.6% and 82.2%. The specificity for the detection was between 96.4% and 98.6% for the total corneal area and 96.6% and 98.0% for the non-vascularised area.

Conclusion

The proposed algorithm showed a high accuracy compared with the measurement made by an ophthalmologist. The study suggests that an automated tool using artificial intelligence may be used for the calculation of the CoNV area from the slit-lamp images of patients with CoNV.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Corneal NeovascularizationArtificial IntelligenceAlgorithmsHumansFemaleMaleMiddle AgedAgedImage Processing, Computer-AssistedNeural Networks, ComputerCorneaAdultDeep LearningSlit Lamp MicroscopyRetrospective Studies

Stichwörter der Autor:innen

CorneaDiagnostic tests/InvestigationImagingNeovascularisationOcular surface

Autor:innen und Institutionen

  • Department of Ophthalmology, Saarland University Medical Center (UKS), Homburg, Saarland, Germany burakmergen@gmail.com.
  • Department of Ophthalmology, University of Health Sciences, Basaksehir Cam and Sakura City Hospital, Istanbul, Turkey.
  • Department of Ophthalmology, Saarland University Medical Center (UKS), Homburg, Saarland, Germany.
  • Saarland Informatics Campus, German Research Center for Artificial Intelligence (DFKI), Saarbrücken, Saarland, Germany.

ORCID-Profile: Burak Mergen, Berthold Seitz

Zitieren

APA

Mergen, B., Safi, T., Nadig, M., Bhattrai, G., Daas, L., Alexandersson, J., & Seitz, B. (2024). Detecting the corneal neovascularisation area using artificial intelligence. British Journal of Ophthalmology, 108(5), 667-672. https://doi.org/10.1136/bjo-2023-323308

Vancouver

Mergen B, Safi T, Nadig M, Bhattrai G, Daas L, Alexandersson J, et al. Detecting the corneal neovascularisation area using artificial intelligence. British Journal of Ophthalmology. 2024;108(5):667-672. doi:10.1136/bjo-2023-323308

BibTeX
@article{Mergen2024,
  author = {Mergen, Burak and Safi, Tarek and Nadig, Matthias and Bhattrai, Gopal and Daas, Loay and Alexandersson, Jan and Seitz, Berthold},
  title = {Detecting the corneal neovascularisation area using artificial intelligence},
  journal = {British Journal of Ophthalmology},
  year = {2024},
  volume = {108},
  number = {5},
  pages = {667--672},
  doi = {10.1136/bjo-2023-323308}
}
Kostenlos starten →